Seav LRX 2281 Manual De Instrucciones página 18

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
C) CODE PED (Hydraulic Motors Maintenance Pressure):
The control unit is supplied by the manufacturer with the hydraulic motors maintenance
pressure function disabled. If you wish to enable the function, proceed as follows: make
sure that you have enabled Extended Menu 1 (T. PAUSA LED and RIT. ANTE LED start flash-
ing alternately), with the SEL key position on the flashing of CODE PED LED then press the
SET key, the PED CODE LED will simultaneously stay on steady and programming is com-
pleted. Accordingly the control unit will send a closing command every 2 hours to the motor
for 2 seconds. Repeat the procedure to restore the previous configuration.
D) CODE PED (Water Hammer):
The control unit is supplied by the manufacturer with Water Hammer disabled. If you
wish to enable the Water Hammer function, proceed as follows: check that Extended
Menu 1 is enabled (RIT. ANTE LED and T. PAUSA LED start flashing alternately), with the
SEL key position on the flashing of INB.CMD.AP LED then press the SET key, the INB.
CMD.AP LED will simultaneously switch on permanently and programming is completed.
If you wish to enable the Water Hammer function to the power set through the "POWER"
Trimmer, repeat the operation described above, pressing the SEL button twice instead
of once (making the INB.CMD.AP. LED flash rapidly). Repeat the operation to restore the
initial configuration.
Accordingly, we can facilitate the release of the gate and therefore allow the proper ex-
ecution of the opening phase. In fact, the control unit, before starting the opening phase
sends a closing command for 2 seconds with power relative to the choice selected.
E) T. MOT. (Closing Hammer):
The control unit is supplied by the manufacturer with the Closing Hammer Function disabled.
If you wish to enable the Closing Hammer function, proceed as follows: make sure that you
have enabled Extended Menu 1 (RIT. ANTE LED and T. PAUSA LED start flashing alternately),
with the SEL key position on the flashing of T.MOT. LED then press the SET key, the T.MOT.
LED will simultaneously switch on permanently and programming is completed. If you wish
to enable the Closing Hammer function to the power set through the "POWER" Trimmer,
repeat the operation described above, pressing the SEL button twice instead of once (mak-
ing the T.MOT. LED flash rapidly). Repeat the operation to restore the initial configuration.
Accordingly the control unit, if functioning with Deceleration during closing, will reach
(after having completed the deceleration closing phase) a time of 1 second with power
relative to the choice selected in order to overcome the gate installed.
F) T. MOT. LED (Safety device 2 / Block):
The control unit is supplied by the manufacturer with the Block input function disabled.
If you wish to enable the function, proceed as follows: make sure that you have enabled
Extended Menu 1 (T. PAUSA LED and RIT. ANTE LED start flashing alternately), by using
the SEL key select the flashing T. MOT. PED. LED and press the SET button: T. MOT. PED.
LED stays steadily lit and programming is complete.
Accordingly the control unit, changes the function provided for Safety Device 2 input (
CN2 no. 9-10 ) in safety block input with the following function: the intervention in any
function phase of the control unit triggers the immediate stop of motion. A further motion
command will be valid as long as the block input has been deactivated and, in any case,
will carry out the automatism closing phase with a pre-flashing interval of 5 sec.
EXTENDED MENU 2
The control unit is supplied by the manufacturer with the possibility of directly selecting
the main menu functions only.
To enable the functions listed in Extended Menu 2, proceed as follows: open Extended
Menu 1 (as instructed in the respective section), then press and hold the SET key for 5
seconds, the T. PAUSA LED and RIT. ANTE LED will flash simultaneously, accordingly,
you have 30 seconds to select the functions of Extended Menu 2 using the SEL and SET
buttons. After another 30 seconds, the control unit returns to the main menu.
EXTENDED MENU 2
Reference LED
LED Off
A) AUT / P-P
Follow Me = OFF
B) CODE
PreFlash. and Cort. L=OFF
C) CODE PED.
Pause Lamp. = OFF
D) INB.CMD.AP
SOFT START = OFF
E) T. MOT.
El. Gate CMD PED = OFF
F) T.MOT.PED.
PUL=PUL - PED=PED
G) T. PAUSA
Flashing beacon ON/OFF simultaneous
H) RIT. ANTE
Flashing beacon ON/OFF in simultaneous
A) AUT/P-P (Follow Me):
It is possible to set the "Follow Me" function on the control unit: this function can only be
programmed if a Pause Time has already been programmed, and it is used to shorten the
Pause time to 5 sec after the DS1 photocell disengages, i.e. the gate closes 5 seconds
after the user has passed through. If you wish to enable the function, proceed as fol-
lows: make sure that you have enabled Extended Menu 2 (T. PAUSA LED and RIT. ANTE
LED start flashing simultaneously), with the SEL key position on the flashing of AUT/ P-P
LED then press the SET key, the AUT/P-P LED will simultaneously switch on steadily and
programming is completed. Repeat the procedure to restore the previous configuration.
B) CODE (Pre-flashing / Courtesy Light):
The control unit is supplied by the manufacturer with Pre-flashing and Courtesy Light
functions disabled. If you wish to enable the Pre-flashing function, proceed as follows:
make sure that you have enabled Extended Menu 2 (T. PAUSA LED and RIT. ANTE LED
start flashing simultaneously), with the SEL key position on the flashing of CODE LED
then press the SET key, the CODE LED will simultaneously switch on permanently and the
programming is completed. If you wish to enable the Courtesy Light, repeat the operation
described above, pressing the SEL button twice instead of once (the CODE LED will flash
rapidly). Repeat the operation to restore the initial configuration.
Pre-flashing** function The flashing beacon 230 Vac is always activated 3 seconds before
the automation starts any type of motion.
Courtesy Light Function: The Flashing beacon 230 Vac output will be activated for 3
minutes, each time that an opening command is given.
C) CODE PED (Flashing beacon function):
The control unit is supplied by the manufacturer with the flashing beacon function during
the enabled Pause Time. If you wish to disable the function, proceed as follows: make
sure that you have enabled Extended Menu 2 (T. PAUSA LED and RIT. ANTE LED start
18
LED On
Follow Me = ON
PreFlash. or Cort. L. =ON
Pause Lamp. = ON
SOFT START = ON
El. Gate CMD PED = ON
PUL=AP - PED=CH
Tabla de contenido
loading

Tabla de contenido