INTRODUCTION
!
WARNING: This unit is intended for professional use. Read all the instructions in this manual prior to use.
• This meter is an oval gear model.
• Only use the unit for the purposes for which it is intended.
• This unit has not been approved for use in commercial
transactions.
• Do not alter or modify the unit.
• Do not exceed the maximum unit working pressure. See
page 7, technical specifications.
• Use the unit with fluids and solutions which are
compatible with the moist parts of the unit. See the
relevant section of the technical specifications.
INSTALLATION
The meter can be connected to a control gun or installed
directly in the distribution line pipe.
It is recommendable to install a cut-off valve before the
meter to facilitate its maintenance or repair.
The meter has a 1/2" BSP connection at the inlet and outlet.
It also includes an inlet flange and a flange at the outlet
BATTERIES
1
3
4
2
SB 3100 R. 01/20
Balcrank Corporation · 90 Monticello Rd. · Weaverville, NC · Tel: 800-747-4261 · www.balcrank.com
• Observe the manufacturer's safety warnings for the
fluids used.
• The meter has been manufactured with low tolerances
in order to ensure high precision over a wide range of
flows and viscosity.
• Check measurement units counter before first use.
• In order to save energy the meter switches off automatically
after 30 seconds of inactivity. All the data are stored for
recovery once the meter has been restarted.
which enables connection for the range of guns and original
BALCRANK accessories.
The meter requires two 1.5 V batteries and size LR 03 as the power
supply source. They are housed in a support which, in conjunction
with the lid design, prevents the batteries from being removed
accidentally in the event of impacts or vibrations.
ATTENTION: The meter is supplied without the batteries
mounted. Follow the procedure below to install them.
Loosen the screws (1) and remove the battery housing
cover (2).
Install the provided batteries (3) checking that the polarity
2
matches the polarity symbols (4) marked in the housing.
Put in place the cover (2) and tighten the screws (1).
WARNINGS
To guarantee the battery cover sealing, ensure
!
that the battery is properly positioned and the
screws tightened.
1
When replacing the batteries the monitor briefly displays
the meter software version.