EN
DESCRIPTION
1. LED diode
2. Hanging handle
3. Cooling fan
4. LCD digital display
5. Button: mode, up, down, enter
6. DMX linking in/out
7. Power supply
INSTALLATION
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to
avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the
unit is secure and is able to support a weight of 10 times of the unit's weight.
Never stand directly below the device when mounting, removing or servicing the fixture.
FIXTURE LINKING
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of
channels required by all fixtures on a serial data link determines the number of fixtures that the data link can
support.
Important: Fixtures on a serial/data link must be daisy chained in one single line. Maximum recommended
serial data link distance: 100 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link:
16 fixtures
DATA CABLING
To link fixtures together you must use data cables. If you choose to create your own cable, please use da-
ta-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
Termination reduces signal errors. To avoid signal transmission problems and interfe-
rence, it is always advisable to connect a DMX signal terminator.
CAUTION
Do not allow contact between the common and the fixture's chassis ground. Groun-
ding the common can cause a ground loop, and your fixture may perform erratically.
Test cables with an ohm meter to check correct polarity and to make sure the pins are not grounded or shorted
to the shield or each other.
NAVIGATION THROUGH THE CONTROL PANEL
Access control panel functions using the four panel buttons located directly underneath the LCD Display..
Button
Function
MENU
Used to access the menu or to return to a previous menu option
UP
Scrolls through menu options in ascending order
DOWN
Scrolls through menu options in descending order
ENTER
Used to select and store the current menu or option within a menu
When a menu function is selected, the display will show immediately the first available option for the selected
menu function. To select a menu item, press <ENTER>.
Master mode: any unit can work as a master
Slave mode: the DMX address value must be set to Slave.
DMX code setting: d1~d512
8.8.8.8.
MENU
UP
DOWN
ENTER
3