INSTALLER MENU (Fig. 8)
In OFF mode, hold OK for 10 seconds to enter the installation menu.
Press ◄► to select the options;
Press ▲▼to modify the values;
AF = Anti-Frost threshold (standard 6.0ºC);
HYS = Switching differential (standard 0,2ºC);
OFS = Offset temperature correction (standard 0.0ºC);
ºC = Celsius / Fahrenheit degrees selection
CLR = Choose YES and wait for 4 seconds to reset and restore factory settings automatically. Press OK
to quit the installer menu.

WIRING CONNECTION