Gardner Denver Thomas AP-30 Operación Manual página 5

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 157
LP or LW Series Filter Element Replacement Instructions:
D
isconnect power.
Remove screw and filter cover.
YP Series Filter Element Replacement Instructions:
It is the responsibility of the end-user to integrate a suitable filtration method.
For replacement filter element part numbers, see pertinent series datasheet on gd-thomas.com.
Integrated Diaphragm Protection Switch
Information
Models AP-60N, AP-60/80, AP-80H, AP-100, AP-120, LP-150HN, LP-200HN, LW-240,
LW-300, LW-400 and YP-70VC are equipped with an integrated diaphragm protection
switch that activates or turns off the pump in case of a diaphragm failure or external
impact. This switch may be deactivated by performing the following instructions:
M
ake sure the main power cord is disconnected before
performing switch deactivation.
I
f the diaphragm is damaged, have the pump serviced by
trained service personnel. (
little or no air flow or higher than normal sound level.)
Applicable AP Series Diaphragm Switch Deactivation Instruction:
D
isconnect power.
Remove four housing screws and housing.
Filter cover screw
AP Housing
(4) Housing screws
Replace filter element, reassemble cover & screw.
D
amage may be detected by
Remove four cover plate
screws and cover plate.
Filter element
Gasket location
(Gasket not shown)
Cover plate
(4) Cover
plate screws
5
Tabla de contenido
loading

Tabla de contenido