ISEO AP101 Folleto De Instrucción página 2

Idiomas disponibles
  • ES

Idiomas disponibles

ISEO Serrature S.p.a.
Via S. Girolamo 13
25055 Pisogne (BS)
Italy
AJUSTING THE OPENING AND CLOSING FORCE:
Calibrate the push force as follows:
- Operate the Actuator and unscrew the torque adjustment Screw until the gate stops.
- Wait 5 or 10 seconds and adjust, by rotating clockwise.
- We recommend using a dynamometer to check that the push force does not exceed 15 Kg.
- Close the gate.
- Adjust the torque delay time to the minimum possible so that the motor can overcome the initial
inertia of the gate.
This determines the start of the gate at the maximum power possible, when the time has
elapsed, a push force equal to the force set by adjusting "Torque Adjustment" trimmer is
delivered.
- Execute several test manoeuvres to check the correct operation of the system.
Kg
MAX. PUSH
0.5
Torque delay time adjustment
Phone No.: 0364/8821
Fax: 0364/86175
Sales Dept. Fax No.: 0364/882263
Made in Italy
AAP101 TORQUE ADJUSTER FOR
ATP SERIES ELECTRO-MECHANICAL ACTUATORS
INSTRUCTION BOOK
Adjustment example
4
For the first ½ second, the motor starts
at the nominal torque and then passes
to the Torque, (set by T2), (after the
SET
delay time set by T1).
TORQUE
sec.
I EO
S
AIC103F/01-97
loading