GiBiDi BA230 Manual De Instrucciones página 32

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66
32
UK
A5
2 MOTORS CONFIGURATION
STEP BY STEP
A6
WITH STOP LOGIC
A7
STEP BY STEP LOGIC
AUTOMATIC / CONDOMINIUM
A8
A9
DEAD MAN LOGIC
Y
Y
Y
Y
LOGIC
Y
It configures the system for 2 motors.
In the menu C11 it will be possible to set the courtesy light
output: surrendering the electric lock 2
N = courtesy light disabled
Y1 = courtesy light disabled
Y2 = courtesy light on ELECTRIC LOCK 2 output (see
diagram 12 Vdc output)
The courtesy light output is 3-minutes timed.
The activation of this menu automatically disables A4.
It enables the STEP BY STEP WITH STOP Logic
Operation:
Start
open
Next Start
stop
Next Start
close
Next Start
open
If automatic closing has been activated (menu C1) and the opening
phase is at the end of the cycle, when the pause time has elapsed
(menu H9), the control unit automatically closes the gate. During pause,
a Start command closes the gate.
Pedestrian command is uninfluential in opening and in pause. In closing
it opens both leaves.
The activation of this menu automatically disables A7-A8-A9.
It enables the STEP BY STEP Logic
Operation:
Start
open
Next Start
close
Next Start
open
If automatic closing has been activated (menu C1) and the opening
phase is at the end of the cycle, when the pause time has elapsed
(menu H9), the control unit automatically closes the gate. During the
pause, a Start command closes the gate.
Pedestrian command is uninfluential in opening and in pause. In closing
it opens both leaves.
The activation of this menu automatically disables A6-A8-A9.
It enables the AUTOMATIC/CONDOMINIUM Logic
Operation:
Start
apre
Next Start(s)
uninfluential if the system is opening or it
reloads the pause time (if the gate is in pause)
and the automatic closing is enabled.
When the pause time has elapsed, if the automatic closing is enabled
(menu C1), the system closes automatically. If the automatic closing is
disabled, Start closes the gate.
If the opening is pedestrian, a pedestrian command closes the gate.
Pedestrian is uninfluential in opening and in pause In closing it opens
both leaves.
The activation of this menu automatically disables A6-A7-A9.
It enables the DEAD MAN Logic
WARNING: 2 motors always operate
Operation:
Start
closes only if the Pedestrian key is held down.
Pedestrian
opens only if the Start key is held down.
In Dead Man's mode the keys on the control unit mean:
Start (Key +)
open
Pedonale (Key -)
close
BA230
Tabla de contenido
loading

Este manual también es adecuado para:

As05550

Tabla de contenido