TechGrow Clima Control Basic Plus 14A Manual página 9

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Installation:
1. It is recommandable to mount the Temp probe
(the stainless steel cylinder) on a suitable
place, preferably +/- 1 meter above the fl oor.
2. Never install the Clima Control Basic Plus near
a water pipe or drainage.
3. Mount the TechGrow Clima Control Basic Plus
to the wall with the supplied mountingkit or to a
DIN-rail.
4. Make sure that the switch is positioned to
"OFF".
5. Plug the fan into the outlet of the Clima Control
Basic Plus.
6. Plug the Clima Control Basic Plus into an
outlet.
7. Done!
Automatic functions of the TechGrow
Clima Control Basic Plus:
Depending on the settings the fan(s) can be
controlled automatically.
After enabling the Clima Control Basic Plus, the
connected fan(s) will always start at full speed
(for 1 second) to guarantee that your box will start
rotating despite of how low the Box Min is set.
After setting the temperature, the Clima Control
Basic Plus will try to maintain this temperature.
LED Display:
When the Clima Control Basic Plus is operating
normally, the LED display will show the current
measured temperature.
After adjusting the set-point, the Clima Control
Basic Plus will display the new set temperature for
three seconds.
In case there's no communication with the sensor,
the display will show "--".
Working of the Clima Control Basic Plus:
The Clima Control Basic Plus controls the
temperature in your area. When the temperature
exceeds the set + hysteresis, the fan power will
slowly increase until the temperature reaches the
set-point or the fan speed reaches the "MAX"
value (whichever comes fi rst). When the
temperature drops below the set - hysteresis, the
fan power will slowly decrease until the
temperature reaches the set-point or the fan
speed reaches the "MIN" value
(whichever comes fi rst).
In case of failure to the sensor the controller will
let the Box power increase until the "MAX" value
is reached.
Confi guring the
Clima Control Basic Plus:
Rotate the temperature button (top left on the
controller) all the way up to 45 °C.
Position the switch to "AUTO".
The fan should now start rotating.
Set the minimum fan power to the desired level by
rotating the Box Min button.
Now, adjust the set-point to 10 °C and set the
maximum fan power by rotating the "MAX" button.
Now set the desired temperature by rotating the
"Temp" button. The set-point will be shown on the
LED display.
Also set the hysteresis by setting the right button
to the desired value (1.0 - 7.0 °C).
Ramping up from Box min to Box may take up to
2 minutes. The adjustment rate of the Clima
Control Basic Plus is calmer than other controllers
so that a more stable climate can be created.
A perfect adjustment can be obtained by playing
with the Box min and Box max.
Do not set the Box min too low to prevent stalling
of your fan.
This setting can be diff erent for every fan.
If desired, the controller can be overruled
(temporarily) to let the fan operate at 100%.
In order to do this, position the swith to "100%".
To continue at normal speed, position the switch
back to "AUTO".
Connecting extra sensors or other
devices:
It is not possible to connect extra sensors to the
Clima Control Basic Plus.
The only sensor suitable for the
Clima Control Basic Plus is the Temp probe which
is pre-mounted by default.
Also, the Clima Control Basic plus can NOT be
connected to other TechGrow devices.
9
Tabla de contenido
loading

Tabla de contenido