Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Sensor Light
As an ENERGY STAR
nith has determined that this product meets
the ENERGY STAR
efficiency. This product is ENERGY STAR
compliant when used with 120 Watt bulbs.
Model SH-5412
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
This package includes:
Rubber Plug
Lamp Holders
Cover
Plate
Sensor
Light Control
Mounting Strap
Mounting Bolt
Plastic
Hanger
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
© 2006 DESA Specialty Products
Motion
Control
Partner, Heath
/Ze-
®
®
guidelines for energy
®
®
2 Shells
Gasket
6 Screws
(3 sizes included)
2 Wire
Connectors
OPERATION
Mode:
On-Time:
Test
5 Sec
Auto
1, 5, 10 min.
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
the circuitry to calibrate.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Works:
Day
Night
x
/
minutes for
1
2
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch off
for one second then
back on*
598-1158-01
x
x
x
Tabla de contenido
loading

Resumen de contenidos para Secure Home SH-5412

  • Página 1 TEST compliant when used with 120 Watt bulbs. ON-TIME Put the ON-TIME switch on the bottom of the sensor in the TEST position. Model SH-5412 10 5 1 TEST Features AUTO • Turns on lighting when motion is detected. • Automatically turns lighting off.
  • Página 2: Wall Mount

    INSTALLATION ❒ Twist the junction box wires and fixture wires together as shown. Secure with wire connectors. For easy installation, select an existing light with a wall Mounting Black to White to switch for replacement. Strap Black White Rubber Plug Wall Mount Eave Mount Mounting...
  • Página 3 TEST AND ADJUSTMENT ❒ Loosen the clamp screw in the Clamp sensor ball joint and gently Screw ❒ Turn on the circuit breaker and light switch. rotate the sensor. ❒ Walk through the coverage Ball NOTE: Sensor has a 1 minute warm up period area noting where you are Joint...
  • Página 4: Troubleshooting Guide

    TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Lights will not come 1. Light switch is turned off. Lights stay on 1. A flood lamp is positioned too close to continuously. 2. F l o o d l i g h t i s l o o s e o r the sensor or pointed at nearby objects burned out.
  • Página 5: Control De Luz Del Detector De Movimiento

    ® minutos para que el circuito se claibre. de 120 vatios. Para PRUEBA: Modelo SH-5412 ON-TIME Ponga el interruptor de tiempo (ON- Características TIME), al fondo del detector, en la • Prende la luz cuando detecta movimiento.
  • Página 6: Instalacion

    INSTALACION ❒ Conecte los cables de la caja de empalme con los cablesdelaparatodeluz,comosemuestra.Tuérazalos Para una fácil instalación escoja una luz con un juntos y asegúrelos con un conector de cables. interruptor de pared. lámina de Blanco a Negro a Montaje Blanco Negro Enchufe...
  • Página 7: Prueba Y Ajuste

    PRUEBA Y AJUSTE ❒ Afloje el tornillo sujetador en la Tornillo unión esférica y gire despacio Sujetador ❒ Prenda el cortacircuitos y el interruptor de luz. el detector. ❒ Camine por el área a prote- Unión NOTA: El detector tiene un período de cerca de 1 gerse y dése cuenta dónde Esférica minutos de calentamiento antes de detectar...
  • Página 8: Guia De Investigacion De Averias

    GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La Luz no se enci- La luz se 1. El interruptor de luz está apaga- 1. Un faro está colocado demasiado cerca ende. queda al detector o apunta a objetos cercanos 2.

Tabla de contenido