Safety Information; Compliance With Standards - Scame ISOLATORS-EX Serie Instalación Uso Y Mantenimiento

Ocultar thumbs Ver también para ISOLATORS-EX Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
ISOLATORS-EX
An example of the label used for the SWITCH - DISCONNECTOR is shown below:
Via Costa Erta 15 Parre BG ITALY
590.XGE2002
TÜV IT 14 ATEX 005
Ex tb IIIC T80°C Db Ta -25°C to + 40°C
Ex tb IIIC T90°C Db Ta -25°C to + 60°C
DO NOT OPEN WHEN ENERGIZED IN PRESENCE OF EXPLOSIVE ATMOSPHERE
590.XGE2002: switch-disconnector in enclosure.
Detail of the product traceability on the adhesive label.
Via Costa Erta 15 Parre BG Italy
Cod.
590.XGE2002
S/N
xxxxxxxxx
TÜV IT 14 ATEX 005
THIS DOCUMENT MUST BE READ CAREFULLY BEFORE INSTALLATION
These instructions are intended for: expert electricians or appropriately trained personnel.

1. SAFETY INFORMATION

The switch - disconnectors in enclosures of the ISOLATORS-EX Series can be used for fixed installations in environments with a
potential risk of explosion, due to the presence of combustible dust, classified as zone 21 and zone 22.
These instructions for installation, use and maintenance must be kept in a safe location for future reference. During operation or
maintenance work on the apparatus, do not leave this manual or other objects inside the enclosure. Use the ISOLATORS-EX Series
switch - disconnectors in enclosures for their approved use only, and keep them completely intact and clean.
The switch - disconnectors in enclosures are designed to withstand shocks of 7 J and to be used under normal vibration conditions.
They are not designed for use in environments subject to extreme vibrations.
The enclosure is made of thermoplastic material. The type of protection cannot be guaranteed if the product is installed incorrectly.
Use only original spare parts supplied by SCAME. No modification/work is permitted on the switch - disconnector in enclosure
unless specifically indicated in this manual.
DO NOT OPEN THE ENERGISED ENCLOSURE IN PRESENCE OF AN EXPLOSIVE ATMOSPHERE
Always follow the national safety rules and the safety instructions contained in this manual when ever working on the device.

2. COMPLIANCE WITH STANDARDS

The switch – disconnectors in enclosure of series XGE and XEM are intended for use in Zone 21 and 22, in compliance with the
provisions of Directive 2014/34/EU:
MP36511
590.XGE3202
Year 2014
TÜV IT 14 ATEX 005
0051
Ex tb IIIC T80°C Db Ta -25°C to + 40°C
IP66
II 2D
Ex tb IIIC T90°C Db Ta -25°C to + 60°C
IP66
DO NOT OPEN WHEN ENERGIZED IN PRESENCE OF EXPLOSIVE ATMOSPHERE
590.XGE3202: 32A switch-disconnector in enclosure.
Year
2014
0051
II 2D
11
Via Costa Erta 15 Parre BG ITALY
WARNING:THE CABLE ENTRY POINT MAY EXCEED 95°C
Year 2014
0051
IP66
II 2D
IP66
ZP90828-5
Tabla de contenido
loading

Tabla de contenido