Health Zenith 6105 Manual De Instrucciones página 3

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

AdJUSTMENTS
There are 6 preset selections for the amount of
time the lights stay on: Test (5 seconds), 1, 5, 10,
15, and 20 minutes. Use a small, phillips screw
driver to adjust the TIME control (see Figure 4).
Turn the TIME control until it "snaps" into the
desired time position.
Light Level
You can adjust the sensor's sensitivity to existing
light. Use a small Phillips screw driver to adjust
the LIGHT control (see Figure 4). By turning the
control fully clockwise, the sensor will turn lights
on even in full daylight. By turning the control fully
counterclockwise, the sensor will only turn lights
on when the existing light is very low.
Adjusting the Photocell
1. When the existing light in the room is at the
level you want the lights to turn on, set the mode
selection switch to the AUTO position.
2. Adjust the TIME control to the 5 second posi-
tion.
3. Adjust the LIGHT control to the minimum
dark position (fully counterclockwise).
4. Wait for the lights to turn off.
5. Slightly turn the LIGHT control clockwise.
Wait 2 seconds, then move your hand in front
of the sensor. If lights controlled by the sensor
do not come on, repeat this step until they do.
The light will now come on when the light level
is at or below the present level and motion is
detected.
Electrical Input ................................................................................................................120V, 60 Hz.
Fluorescent Load ...................................30 Watts minimum, Up to 400 Watts Maximum Rapid Start
Motor Load ...................................................................................................Up to 1/8 HP Maximum
Incandescent ...........................................................................Up to 500 Watts Maximum at 120VAC
On-Time ..........................................................................Adjustable approximately 5 sec. to 20 min.
Photocell Sensor ........................................................................ From full daylight to less than 1 FC.
Coverage ................................ up to 15 ft. (4.6 m) at 150°, up to 30 ft. (9.1 m) in front of the sensor
HeathCo LLC reserves the right to discontinue products and to change specifications at any time
without incurring any obligation to incorporate new features in products previously sold.
595-4881-11
Time
SPECIFICATIONS
Any Light Level
5
10
1
Test
20
T I M E
5 Seconds
Figure 4 - Time and Light Adjustments
COMPLETING INSTALLATION
1. Replace control panel cover and attach the
decorative wall plate. In installations where
the Heath
®
/Zenith motion sensor switch is
combined with other switches or outlets on
an expanded box, you will need to purchase
a combination wall plate. Various combination
wall plates are available at home centers and
electrical supply stores.
2. Slide the mode selection switch a couple times
to make sure it moves freely.
USING MOTION SENSOR
WALL SWITCh
MOdE SELECTION SWITCh
This switch allows you to selects one of three
modes of operation: OFF, AUTO, or ON.
OFF: Lights stay off.
AUTO: Lights automatically come on when
motion is detected and the existing light is below
the set level.
ON: Lights stay on continuously.
3
Dark (low light level)
+
15
L I G H T
20 minutes
Tabla de contenido
loading

Tabla de contenido