Place dehumidifier inside area to be dried. Make sure
all windows and doors are closed to the outside and
seal off the wet area from any unaffected areas. Route
condensate hose into a drain or a very large container.
START-UP MODE
Turn the dehumidifier on or off by
pressing the power button.
(See Figure 1) When the
dehumidifier is started, the hour
meter will briefly display the
software version number, followed
by the cumulative hours.
The unit will go into off mode immediately when the
power button is pressed during the first minute of
operation.
RUN MODE
During run mode, the compressor is running, causing
the evaporator to get cold, resulting in condensate
forming on the coil.
The unit will stay in run mode for a variable length of
time, depending on the ambient conditions.
Pressing the power button will send the unit into shut
down mode. (See Figure 1)
LOSS OF POWER RECOVERY FUNCTION
In case of a loss of power, the last run state (on or off)
will be maintained when the power is restored.
PUMP PURGE FUNCTION
In normal operation, the pump will
automatically empty the reservoir.
Pressing the purge button runs
the pump for 1 minute, allowing
manual emptying of the reservoir.
(See Figure 3) The pump purge will
function in all modes as long as
the unit is plugged in.
PAGE 2 OF 15
OPERATION
DEFROST MODE
During the defrost mode, the
indicator light will turn on, the
compressor will be off and the
fan will continue to run. (See
Figure 2) The pump purge will be
activated automatically.
Figure 1
The defrost cycle runs every 45 minutes in cool ambient
temperatures, less often in warm ambient temperatures,
and the length of time in defrost will vary appropriately.
Heavy frosting on the coil can be expected during low
ambient temperatures and will not affect the operation
of the unit.
SHUTDOWN MODE
Pressing the power button after the first minute of
operation will initiate a shut down mode. This mode will
last 15 minutes and will maintain the operation of the
fan and purge the pump to ensure all water is removed
from the unit prior to moving or storing. Pressing the
power button at any time during the shutdown mode
will immediately shut down the unit and bypass the
remainder of the shutdown mode. The unit must be
purged by pressing the purge button if bypassing the
shut down mode to avoid water overflow.
The display will change during shut down mode to a
countdown timer that will indicate the time remaining
before the unit shuts completely off.
FUNCTIONS
HOUR METER DISPLAY
The cumulative hours will
be displayed during normal
operation. If the unit is off (even
unplugged), pressing the hour
button will also display the
accumulative hours briefly.
Figure 3
(See Figure 4)
VENTING / DUCTING
Twin rear outlets can
accommodate two individual
5" ducts or one 10" lay-flat duct
to be attached (not included).
This allows for warm, dry air to
be directed into different areas.
(See Figure 5)
Figure 2
Figure 4
Figure 5
0721 IH-6621