Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area, after
installation. If it not fitted with a plug (direct mains connection)
or if the plug is not located in an accessible area, after
installation, apply a double pole switch in accordance with
standards which assures the complete disconnection of the
mains under conditions relating to over-current category III, in
accordance with installation instructions.
WARNING!
Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains
cable is correctly assembled.
The hood is provided with a special power cable ; if the cable
is damaged, request a new one from Technical Service.
Mounting
This type of cooker hood must be fixed to the ceiling.
Very heavy product; hood handling and installation must
be carried out by at least two persons.
Before beginning installation:
•
Check that the product purchased is of a suitable size for
the chosen installation area.
•
Remove the charcoal (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
•
Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood.
Do not tile, grout or silicone this appliance to the wall.
Surface mounting only.
Operation
Models with Soft Button panel + LCD Display
1
ON/OFF motor
Pressing the button, the hood turns on at speed 1.
Pressing the button during functioning, the hood turns
OFF.
2
Speed Increase
Pressing the button the hood passes from the OFF state
to speed 1.
Pressing the button (hood in ON state) the motor speed
is increased from speed 1 to intensive.
To each speed corresponds the ignition of the respective
led.
Speed 1: 1
Speed 2: 2
Speed 3: 3
Intensive Speed: 4 (flashing)
The intensive speed is timed. The standard timing is 5',
at the end of which the hood positions itself to speed 2.
To deactivate the function before the time expires press
key 2, the hood positions itself to speed 1, pressing key 1
the hood will turn off.
3
ON/OFF lights
4
Speed timing
5
Function state indicator
Speed Timing
The timing of the speed is enabled by pressing key 4, once
the timing expires the hood turns off.
The timing is subdivided as follows:
Speed 1 - 20 minutes (1 fixed, flashing point)
Speed 2 - 15 minutes (2 fixed, flashing point)
Speed 3 - 10 minutes (3 fixed, flashing point)
Intensive Speed - 5 minutes (4 fixed, flashing point)
During time-running, if key 1 or 4 is pressed, the hood turns
off; if key 2 is pressed, the hood stops time-running and sets
to the selected speed.
Grease filter signalling
The grease filter is signalled by the display with number 1
flashing after 80 hours of use.
This means that the grease filter needs to be washed.
The signalling is visible with the hood in ON state.
To eliminate the grease filter signalling, press key "1" for
more than 3", until it turns off.
The signalling can be eliminated with the hood in ON state.