IntesisBox
KNX - Daikin A/A (Gama Doméstica)
95
FE
96
FF
97
J0
98
J1
99
J2
100
J3
101
J4
102
J5
103
J6
104
J7
105
J8
106
J9
107
JA
108
JH
109
JC
111
JE
112
JF
113
L0
116
L3
117
L4
118
L5
119
L6
120
L7
121
L8
122
L9
123
LA
125
LC
129
P0
130
P1
132
P3
133
P4
134
P5
135
P6
136
P7
142
PJ
145
U0
146
U1
147
U2
148
U3
149
U4
150
U5
151
U6
152
U7
153
U8
154
U9
155
UA
156
UH
157
UC
158
UJ
159
UE
160
UF
209
60
210
61
211
62
212
63
213
64
214
65
217
68
219
6A
220
6H
221
6C
222
6J
223
6E
224
6F
226
51
227
52
228
53
229
54
241
40
© Intesis Software S.L. Todos los derechos reservados
La información en este documento está sujeta a cambios sin previo aviso
IntesisBox es una marca registrada de Intesis Software SL
Oil pressure abnormal
Oil level abnormal
Sensor system error of refrigerant temperature
Pressure sensor error
Current sensor error
Discharge pipe thermistor system error
Low pressure equivalent saturated temperature sensor system error
Suction pipe thermistor system error
Heat exchanger(1) thermistor system error
Heat exchanger(2) thermistor system error
Oil equalizer pipe or liquid pipe thermistor system error
Double tube heat exchanger outlet or gas pipe thermistor system error
Discharge pipe pressure sensor error
Oil temperature sensor error
Suction pipe pressure sensor error
Oil pressure sensor error
Oil level sensor error
Inverter system error
Temperature rise in a switch box
Radiation fin (power transistor) temperature is too high
Compressor motor grounded or short circuit, inverter PCB fault
Compressor motor grounded or short circuit, inverter PCB fault
Over current of all inputs
Compressor over current, compressor motor wire cut
Stall prevention error (start-up error) Compressor locked, etc.
Power transistor error
Communication error between inverter and outdoor control unit
Shortage of refrigerant (thermal storage unit)
Power voltage imbalance, open phase
Sensor error of temperature rise in a switch box
Radiation fin temperature sensor error
DC current sensor system error
AC or DC output current sensor system error
Total input current sensor error
Capacity setting error (outdoor)
Low pressure drop due to insufficient refrigerant or electronic expansion valve error, etc.
Reverse phase, Open phase
Power voltage failure / Instantaneous power failure
Failure to carry out check operation, transmission error
Communication error between indoor unit and outdoor unit, communication error between
outdoor unit and BS unit
Communication error between remote control and indoor unit / Remote control board failure or
setting error for remote control
Communication error between indoor units
Communication error between outdoor units / Communication error between outdoor unit and
ice thermal storage unit
System
Communication error between main and sub remote controllers (sub remote control error) /
Combination error of other indoor unit / remote control in the same system (model)
Communication error between other indoor unit and outdoor unit in the same system /
Communication error between other BS unit and indoor/outdoor unit
Combination error of indoor/BS/outdoor unit (model, quantity, etc.), setting error of spare parts
PCB when replaced
Improper connection of transmission wiring between outdoor and outdoor unit outside control
adaptor
Centralized address duplicated
Attached equipment transmission error
Communication error between indoor unit and centralized control device
Failure to carrey out check operation Indoor-outdoor, outdoor-outdoor communication error,
etc.
All system error
PC board error
Ozone density abnormal
Contamination sensor error
Indoor air thermistor system error
Outdoor air thermistor system error
HVU error (Ventiair dust-collecting unit)
Dumper system error
Door switch error
Others
Replace the humidity element
Replace the high efficiency filter
Replace the deodorization catalyst
Simplified remote controller error
Fan motor of supply air over current or overload
Fan motor of return air over current / Fan motor of return air overload
Inverter system error (supply air side)
Inverter system error (return air side)
Humidifying valve error