X1, X2, M12 plug, A-coded
Pin No. X1
signal
1
+24 V DC
2
OSSDA2
safe switching output
3
0 V
4
OSSDA1
safe switching output
FE
Connect the M12 housing/cable shield to the functional earth via the
RSL housing
It is possible to operate the device in industrial applications with un-
shielded interconnection cables. The use of shielded interconnection ca-
bles is, however, recommended.
NOTICE
Pins 2 and 3 of the X2 plug must not be contacted.
Technical data of the MELD signal output
The MELD signal output can be accessed via the switching contact and is electri-
cally isolated through a relay.
Output contact
Switching capacity of the contact acc. to
EN/IEC 60947-5-1
Max. contact voltage
Permissible contact current
Ext. contact fuse protection
Max. switching frequency
Mechanical life time
Pickup delay
Regression delay
X2
signal
MELD IN
N.C.
N.C.
MELD OUT
1 NO contact
DC13: 24 V / 100 mA
5
1x10
switching cycles
U
<= 30 V
max
0.5 mA <= I
<= 100 mA
max
1 A delay-action
0.5  H z
6
50x10
 switching cycles
5 ms
5 ms