xxi) Leave the Teflon to dry (for the time required according to the instructions of the
product used).
xxii) Skip step 2) and go on to step 3).
13) Mount the nozzle on the water outlet ③.
14) Fasten the anchor bolts (⑤c) to the ground.
NOTE: Level the unit so that the water outlet works properly:
With lighting. Level the unit so that the water line is 1 cm below the LED's lens.
Without lighting. Level the unit so that the nozzle's water outlet is 12 cm above the
water line.
15) Fasten and level the unit at each of its fastening points ⑤ using:
A set of nuts and washers (⑤a) on the top.
Another set of nuts and washers (from top to bottom) on the bottom (⑤b).
2.2
WIRING
WARNING: Risk of damage to the unit. Clean all piping prior to connecting and starting the
unit up.
WARNING: Risk of damage to the unit. Check that all IP68 connectors are properly sealed and
that they prevent water getting through. Electrical components may become damaged by
flooding and the unit could lose its warranty.
WARNING: For greater reliability when the unit is working, it is recommended that the power
cable and control cable be wired separately.
WARNING: The control panel is connected to the unit through an EtherCAT communication
protocol.
16) Connect the unit's water inlet (①).
17) Connect the Ethernet to the control panel (⑥e).
IMPORTANT: Follow the tightening torque instructions to close the waterproof box with
an RJ45 connector (⑪).
18) Connect the unit's main power supply to mains (230 V AC) using the black cable's IP68
connector (⑥u):
L(1): live (brown core wire)
N(2): neutral (blue core wire)
E(3): earth (green and yellow core wire)
INFORMATION: The ⑥m connection (orange wiring) is for the servomotor's power supply.
This connection must not be handled.
Installation, operation and maintenance manual; Dancer jet
[en]
Fountain units
19