Planning

Identify the type and height of your garage door. Survey
your garage area to see if any of the conditions below
apply to your installation. Additional materials may be
required. You may find it helpful to refer back to this page
and the accompanying illustrations as you proceed with
the installation of your opener.
Depending on your requirements, there are several
installation steps which may call for materials or
hardware not included in the carton.
• Installation Step 1 – Look at the wall or ceiling above
the garage door. The header bracket must be securely
fastened to structural supports.
• Installation Step 5 – Do you have a finished ceiling in
your garage? If so, a support bracket and additional
fastening hardware may be required.
• Installation Step 11 – Depending upon garage
construction, extension brackets or wood blocks may
be needed to install sensors.
• Installation Step 11 – Alternate floor mounting of the
safety reversing sensor will require hardware not
provided.
SECTIONAL DOOR INSTALLATION
Horizontal and vertical reinforcement
is needed for lightweight garage doors
(fiberglass, steel, aluminum, door with
glass panels, etc.). See page 23 for details.
Vertical
Centerline
of Garage
Door
Safety Reversing Sensor
Header Wall
Torsion Spring
Gap between floor
and bottom of door
must not exceed 1/4" (6 mm).
• Do you have an access door in addition to the garage
door? If not, Model 139.53702 Emergency Key
Release is required. See Accessories page.
• Look at the garage door where it meets the floor. Any
gap between the floor and the bottom of the door must
not exceed 1/4" (6 mm). Otherwise, the safety reversal
system may not work properly. See Adjustment Step 3.
Floor or door should be repaired.

SECTIONAL DOOR INSTALLATIONS

• Do you have a steel, aluminum, fiberglass or glass
panel door? If so, horizontal and vertical
reinforcement is required (Installation Step 12).
• The opener should be installed above the center of the
door. If there is a torsion spring or center bearing plate
in the way of the header bracket, it may be installed
within 4 feet (1.22 m) to the left or right of the door
center. See Installation Steps 1 and 12.
• If your door is more than 7 feet (2.13 m) high, see rail
extension kits listed on Accessories page.
FINISHED CEILING
Rail
Extension Spring
OR
Wall-
mounted
Access Door
Door
Control
Safety
Reversing
Sensor
Header
Wall
Garage
Door
4
Support bracket &
fastening hardware
is required.
See page 16.
Motor unit
CLOSED POSITION
Header
Bracket
Trolley
Trolley
Stop Bolt
Garage
Door
Spring
Straight
Emergency Release
Door
Rope & Handle
Arm
Curved
Door
Arm
Door
Bracket
Belt

Capítulos