TO STOP HEATER
1. Securely close valve on the propane
cylinder.
2. Continue to operate heater until all fuel in
the hose has burned.
3. Shut off main burner. Do this by turning
control knob to the OFF position. Make
sure you turn the knob until it stops.
TO START HEATER
1. Open propane supply valve on propane
tank(s) slowly. NOTE: If not opened slow-
ly, excess-flow check valve on propane
tank may stop gas flow. If this happens,
you may hear a click inside the regulator
assembly, this is the check valve closing.
To reset the excess-flow check valve,
close propane supply valve and open
again slowly.
WARNING: BEFORE LIGHT-
ING PILOT, turn control knob
clockwise to the OFF position.
2. Press the red button on the safety valve
admitting gas to the pilot. Push and
release the ignition button until the pilot
lights. Hold valve button down for a max-
imum of 30 seconds while attempting
ignition. If heater does not ignite, release
control knob and wait 3 minutes before
attempting reignition. Note: Keep hands
and face away from outlet (around top of
shell) of heater while attempting to start
heater.
3. When pilot remains lit, set heater at the
desired heat level by turning control knob
counterclockwise. If burner goes out, turn
off gas. Turn control knob fully clockwise
to the OFF position. Check fuel supply. If
adequate fuel is available, restart heater
beginning at step #1.
160311-02B
OPERATION
1. Securely close valve at propane cylinder.
2. Wait 5 minutes.
3. Restart following steps under To Start
200,000 BTU MODEL
1. Tightly close propane supply valve on
2. Shut off main burner. Do this by turning
1. Wait five minutes after stopping heater.
2. Restart heater by following steps under
Ignitor
Button
www.usaprocom.com
TO RESTART HEATER
Heater, page 6.
TO STOP HEATER
propane tank(s). Allow heater to burn
remaining fuel in hose.
control knob fully clockwise to the OFF
position. Make sure you turn the knob
until it stops.
TO RESTART HEATER
To Start Heater.
Control
Safety
Knob
Valve
Figure 6 - 200,000 BTU Controls