Degree of separation, machine, EN 60335-2-69, Appendix A-A, Class H [%]
Filter classification, EN 1822-1
Sound level [dB(A)]
o
Air temperature max [
C]
*/ Sound pressure level at 1.6 m height and 1 m distance according to DIN EN ISO 3744 in free field measurement at maximum
air flow.
Operation
Connection
Connect the machine to an electrical outlet with a voltage as per the machine's rating plate specifications.
Starter box:
1. Start button
2. Warning light
3. Stop button
The warning light comes on in the event of a fault. For more detailed descriptions, refer to the Troubleshooting chapter.
If the warning light comes on at startup, this is due to a phase fault. Change the phase direction of the connector on the
connection cable.
Overload protection. The machine is equipped with overheating protection. A thermal cutoff is located in the machine, switchable
at 100°C. In these situations, it is important to investigate the cause of the overheating. Turn off and disconnect the power supply,
and then wait for the machine to cool down (this can take up to 30 minutes).
18
1
2
DC 5900, Art.nr. 42838-J
9,2 kW P, c/a/L
9,2 kW S, c/a
99,995
99,995
HEPA H13
HEPA H13
75
75
30
30
3