OPERATING THE HOSE REEL
1. Slowly pull the dual hose (47). You will hear a clicking noise.
2. To latch or lock the dual hose in place, pull out a minimum of 2 clicks, then slowly allow it to retract to the previous clicking
position.
3. To unlatch or unlock the dual hose, slowly pull the dual-hose until the clicking noise stops completely, then allow and completely
retract into the hose reel.
NEVER retract the dual hose while the gases are on or the torch is lit.
NEVER allow the dual hose to retract quickly and without controlling the coil speed.
NEVER let go of the end of the dual hose when it is rewinding.
MAINTENANCE
Always SHUT OFF and disconnect gas tanks and regulators and purge all gases from the system before
attempting any maintenance.
Note: Always wear safety goggles during maintenance and make sure the hose reel is not connected to the acetylene tank and/or
oxygen tank.
ADJUSTING SPRING TENSION
1. Pull out 6 feet of hose (47) and allow the drum (27, 28) to latch.
2. Remove the bumper blocks (48) by taking out the screws (49) and nuts (50).
3. Feed the dual-hose back through the support plate (2).
4. To increase the hose tension, wrap the pulled hose one time around the drum (27, 28).
5. Reinsert the hose through the support plate (2) and reinstall the bumper blocks (48) by replacing the screws (49) and nuts (50).
6. Check the tension by pulling out the dual hose and releasing it.
7. If necessary, reposition the bumper blocks (48) by taking out the screws (49) and nuts (50), changing their position and replacing
the screws (49) and nuts (50).
HOSE REPLACEMENT
Replace the dual hose only with hoses intended for oxygen and acetylene welding.
1. Remove the support plate (2) by removing the bolts (12).
2. Pull the dual hose (47) out of the final latched position. Make sure it is securely locked and cannot rotate back.
3. Remove the clamp (51) that attaches the dual hose to the drum (28). Detach the dual hose from the outlets. Remove both hose
protection springs (46).
4. Remove the old hose and remove the bumper blocks (48) as explained above.
5. Feed the new hose through the guide on the support plate (2) and the cut out on the drum (27, 28) flange. Replace the hose
protections springs (46) and connect the hose to the outlets. Make sure to apply thread sealant or tape (not included) to the outlets'
threads. Reinstall the clamp (51) and bumper blocks (48).
6. Carefully and slowly, release the drum by gently pulling then releasing the locking ratchet. Then, slowly allow the dual hose to
retract onto the reel.
Note: If the spring encasement requires repair or replacement, take the unit to an authorized technician.
I
'
'
NSTRUCTIONS D
ASSEMBLAGE ET D
UTILISATION
Félicitations pour l'achat de ce produit Mäktig de qualité !
Veuillez lire et conserver ces instructions. Lisez ce document au complet avant d'assembler et d'utiliser ce produit. Tout manquement
aux instructions ou aux avertissements pourrait entraîner des blessures et causer des dommages au produit et à la propriété.
DÉBALLAGE
Lors du déballage, vérifiez que la liste des pièces de la dernière page est incluse et que toutes les pièces sont présentes. Si des
pièces sont manquantes ou endommagées, communiquez avec votre fournisseur le plus tôt possible.
INSTALLATION
Note: Pour un montage au plafond, soulevez suffisamment le dévidoir du sol pour qu'il n'entre jamais en contact avec les passants
ou l'équipement.
Avant de percer des murs ou des plafonds, il est conseillé de vérifier s'il y a présence de
fils électriques devant ou derrière les surfaces de travail qui doivent être percées.