Tabla de contenido

PROGRAMMING

Assign a
User Code
Press (0)
+
Memory position from 01 to 99
Keypad
TX2
Proximity
Reader
Remote
Reader
Enter new code
(1 to 8 digits)
Present Card/Tag
before the Reader*
Press Channel 1 or 2 on TX2
Remote in front of VI200-R*
Notes
Memory Position for User Code is always 2 digits
* no need to validate with A
Assign Examples
Ex.1: To assign User Code "12345" at Memory Position "5" and Relay 1 (10A) in Latch Mode assuming Master Code = 000
Press 000B + 0 + 05 + 12345 + A + 3 + 05 + 1 + A + 1 + 00 + A + B.
Ex. 2: To assign User Code "6789" at Memory Position "6" and Relay 2 (10A) that activates for 5 seconds assuming Master Code =
000
Press 000B + 0 + 06 + 6789 + A + 3 + 06 + 2 + A + 2 + 05 + A + B.
See: Assign a User code
above
Enter "Master Code" OR "000" (if first time use)
Validate by pressing (B)
Validation OK?
Yes
1 small beep + 1 long beep + Yellow LED is 'on'
Change
Assign Output
Master code
Press (3)
Press (0)
+
+
Memory position from
Memory
(01 to 99)
position (00)
+
Press (1) for Relay 1
OR
Press (2) for Relay 2
OR
Press (12) for both
Press A to validate
Validation
Press B (Yellow LED is 'off')
See: Assign Output
above
www.xprgroup.com
Start
Multiple small beeps
No
+
Yellow LED blinks rapidly
Set Output Timer
Pulsed Mode (01 to 99 sec):
Relay 1 (10A):
Press (1) + (from 01 to 99)
Relay 2 (10A):
Press (2) + (from 01 to 99)
OR
Latch Mode (ON/OFF):
Press (1) or (2) + (00)
No
OK?
Yes
End
See: Set Output Timer
above
Delete Single
Delete All Codes
Code
Press (8)
Press (9)
+
+
(99)
Memory position from
(01 to 99)
6
Tabla de contenido
loading

Este manual también es adecuado para:

Vi200r

Tabla de contenido