Lamp Change - Prilux Berlin ECO TUBO LED Manual Del Usuario

Idiomas disponibles

Idiomas disponibles

Berlin ECO
TUBO LED
1x
600mm
1200mm
1500mm
Voltage
Electrical isolation
Degree of waterlightness
Module impact resistance
PROPERTIES:
• IP65 waterproof screen.
• Body and diffuser in polycarbonate.
• Suitable for installation on normally flammable surfaces.
PRECAUTIONS:
• Disconnect power before handling the product and reset it after handling
or installation is complete
• This product must be installed by qualified personnel, in case of doubt
consult a specialized technician.
• Keep it away from children.
• Do not handle the product with wet hands.
• For storage, store the product in a dry place, protected from shocks and
humidity.
• This product is for outdoor use, IP65, do not pierce it and in case the product
shows symptoms of being broken, replace it with a new one.
• If the product or polycarbonate diffuser is damaged, replace it with a new
one immediately.
SURFACE MOUNT:
1. Turn off the power.
2. Drill the surface on which the luminaire will be installed, respecting at all
times the distance between the anchors of each screen (see table).
3. Fix the anchors included in the luminaire to the surface.
4. Remove the fixture mounting plate that holds the fluorescent tubes. To do
this, press the fastening tabs that fix it.
5. Attach the display body to the previously attached anchors.
6. Pass the supply lead through the gland, making sure it is secure. Take care
to make a hole as small as possible so that it fits into the power cable and
ensures tightness.
1/4
julio 2020
2x
85
125
660mm (6 clips)
1270mm (8 clips)
1570mm (10 clips)
ELECTRICAL CHARACTERISTICS
DEGREE OF PROTECTION
BEFORE INSTALLING THIS PRODUCT, PLEASE READ THE
INSTRUCTIONS CAREFULLY AND STORE THEM IN A
SAFE PLACE.
THE INSTALLATION SHOULD BE CARRIED OUT BY
TRAINED STAFF.
INCORRECT HANDLING OF THE PARTS OR THE LIGHT
FIXTURE ITSELF MAY IMPAIR THE PROPER PERFORMANCE
OF THIS PRODUCT. IN THIS CASE, THE MANUFACTURER
GUARANTEE SHALL BE DEEMED VOID.
THE MANUFACTURER GUARANTEE SHALL BE DEEMED
VOID: IF THE INSTALLATION IS NOT PERFORMED IN
ACCORDANCE WITH THE SPANISH LOW VOLTAGE
ELECTROTECHNICAL REGULATION 2002 (REBT 2002).
7. Connect the wires to the connection terminal, noting that the green-
yellow wire is the grounding wire and is marked with the symbol:
8. Attach the carabiners in the housing to the metal plate. (These will hold
the plate when it is necessary to carry out maintenance work without
having to take the luminaire off the hook).
9. Replace the plate, using the fastening tabs.
10. Attach the diffuser using the supplied clips.
11. Restore current.
For the suspended installation of the luminaire follow the steps previously
described but fix the screws installed in the ceiling to the luminaire by means
of a steel chain or cable that ensures the correct fixing of the luminaire and
that it cannot fall.
You have the possibility of linear mounting of the luminaires, respecting, for this,
article 2 of the REBT and ITC-BT-19 of the REBT 2002:
Make a hole in the side opposite the cable gland that is made in the luminaire.
• Fix the second cable gland included in the luminaire, ensuring its correct
placement to guarantee the tightness of the luminaire.
• Pass the power cable through the second gland to connect the next
luminaire.

LAMP CHANGE:

1. Disconnect current
2. Remove the diffuser from the luminaire using the fixing clips.
3. Rotate the tube 90º and pull it out.
4. Insert the ends of the new tube into the holes of the lamp holder and turn
it so that it is fixed respecting the polarity of the led tube.
5. Close the luminaire again.
6. Restore current.
NOTE
230V
IP65
IK08