NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON RESPECT OF THE FOLLOWING
POINTS WILL AUTOMATICALY CAUSE THE CANCELLATION OF THE WARANTY OF THE PRODUCT
Before any opera on on the float remember to disconnect the power supply from the main power.
Ÿ
Check that the maximum motor power does not exceed the float's electrical values.
Ÿ
In case of cable damage by the final user or installer, the float must be replaced.
Ÿ
Do not make any joint on the cable of the float switch, as immersion of such joints could cause short circuits or
Ÿ
electrical shocks.
The maximum slope for proper func oning is 3° (Fig.5)
Ÿ
USE:
The float is a level controller that allows the user to bring the water levels at certain heights with a minimum and
maximum range (Fig.6): increase or decrease the distance between the floa ng units of maximum (a) and minimum (b)
level unscrewing the screw (c) fastened to the floa ng unit by means of a screwdriver with cross head and screwing with
force. Make sure that the floa ng unit is locked securely. The water will act on the floa ng body when it is approximately
half of this. It's possible to set the opera on of the float in automa c (ON / OFF) or manual (always ON) via the manual
switch on the head of the float (d).
The tank fills
the whole floa ng body
TECHNICAL FEATURES:
- Protec on Grade: IP68
- Features of automa c ac on: 1B (micro-disconnec ons in opera on)
TERMINAL CONNECTIONS:
The upstream circuit must protect the electric wires from the overcurrent. WARNING: lack of protec on shall null and
void the warrany in the event the float breaks
.Mod.01: single func on - only emptying or only filling (Fig.1). The grounding wire is always yellow and green.
Ÿ
Mod.02 – Mod.03 double func on (the fi er can choose the emptying Fig.2 or filling Fig.3 when installing):
Ÿ
Emptying: (Fig.2) when black and brown wires are used, the circuit opens when float is down and closes when the
float is up. Note: the blue/grey wire must be insulated.
Filling: (Fig.3) when black and blue/grey wires are used, the circuit closes when float is down and opens when the float
is up. Note: the brown wire must be insulated.
Fig.1
L
Brown
Blue/Grey
N
Yellow/Green
M
The water reaches the
max level. and it raises
L
N
ENGLISH
max
ON
High level starts the
pump and the tank
drains
weight of the floa ng body
Fig.2 emptying
Black
Brown
Blue/Grey
M
The water reaches the
minimum level and the
disengages the magnet
- Pollu on Degree: 2
Fig.3 filling
Black
L
Blue/Grey
N
M
min
OFF
Low level stops the
pump
Brown