Accende/spegne il disposi vo
On / Off
F
Accede al menu informa vo
NL
Access to info menu
Accede ai menu
P
Access to menu level
S
Incrementa la variabile in modifica
Increase the set variable
DK
TEMPERATURE SETPOINT
FIN
Pressing the MENU key, with the selected M1 frame, accesses the temperature set setting. The access is
foreseen with USER password only if is not euqual to zero. The new setpoint value is set with the UP/DW
B
keys. The minimum and maximum limits are defined by SLL and SLH parameters (see controller board
parameters). Confirmation of the new value occurs by pressing the MENU key. To exit the menu without
GR
saving the value, press the ESCAPE key.
CZ
EE
LV
LT
H
TEMPERATURE LIMITS
Pressing the MENU key, with the selected M3 frame, accesses the setting of the high and low temperature
M
limits, absolute or relative references and alarm delay time. The access is foreseen with USER password only
if different from zero. The first value that appears refers to the high temperature limit, is set using the UP/DW
PL
keys and confirmed with the MENU key. The following values that appear after confirmation are the low
temperature limit, the absolute values or relative value to the temperature setpoint and finally the alarm delay
SK
time. The resulting values appear in the absolute or relative limit setting frame. To exit the menu without saving
the value, press the ESCAPE key.
SLO
DEFROST START
Pressing the MENU key, with the selected M4 frame, start a defrost phase only if the conditions exist for it to be
carried out. Otherwise it returns the negation.
WAITING PHASE
The defrost start can contemplate a waiting phase in which the timer 00:00 does not increase the time until the
start.
ACTIVE PHASE
During defrosting the bar will populate from left to right and the timer will start counting. The value at the center
of the frame indicates the coldroom temperature and the value at the left the evaporator temperature.
STOP DEFROST
The defrost can be interrupted by pressing the MENU key during the waiting and active phases, but not
dripping. At the defrost end display will returns to the home page. If a dripping time is setting, the drop icon will
appear and at the end will return to the Home Page.
AUTOMATIC DEFROST
If the defrost is started automatically, the DEFROST window does not appear but display shows Home Page
with defrost action icon.
D1
R290
Accende/spegne la luce vano
Light on/off
Avvia il pia o girevole o ele ropistone
Start the turntable
Esce dal menu; imposta intero/decimale
Escape; set decimal/integer
Decrementa la variabile in modifica
Decrease the set variable
9