EQUYSIS EF-D34 Manual Del Usuario página 35

Tabla de contenido
Main Menu
Sub Menu
Damping Time (3.1)
Pulse Out Mode (3.2)
Pulse Out Unit (3.3)
Max. Freq. (3.4)
Curr. Mode (3.5)
I/O Signal
4mA Fine-Tune (3.6)
Set (3)
20mA Fine-Tune (3.7)
Input1 Func. (3.8)
Input1 Type (3.9)
Filter Variation (3.10)
Filter Weight (3.11)
Main Menu
Sub Menu
Max. Flow (4.1)
Min. Flow (4.2)
Empty Tube Set (4.3)
Output 1 Func. (4.4)
Output 1 Type (4.5)
Alarm Set (4)
Output 2 Func. (4.6)
Output 2 Type (4.7)
Curr. Func. (4.8)
Alarm Curr. (4.9)
Temp. Alarm.(4.10)
Unit
Read Only
second
3
none
Pulse NO
Unit/pulse
0.1 L
kHz
2K
none
4-20
count
0
count
0
N/A
none
N/A
NO
m/s
1
%
10
Unit
Read Only
Flow Rate Unit
Max.
Flow Rate Unit
Min.
N/A
Disable
Max. Flow
N/A
Rate
N/A
NO
N/A
Min. Flow Rate Max. Flow Rate, Min. Flow Rate, Empty Tube, System Alarm
N/A
NO
N/A
none
mA
3.6
N/A
1
www.equysis.com
MANUAL - MEDIDOR ELECTROMAGNÉTICO
Setting Range
0~100
Pulse NO, Pulse NC, Frequency
0.001~100(L,gal, m3,g,kg,Ton) L/pulse,gal/pulse, m3/pulse,g/
pulse,kg/pulse, Ton/pulse
0.001~8K (00.000)
4-20,0-20
-5000~5000
-5000~5000
None, Total Reset
NO,NC
00.000~10.000
0~100
Setting Range
Max. Flow Rate
Min. Flow Rate
Enable, Disable
Max. Flow Rate, Min. Flow Rate, Empty Tube, System Alarm
NO,NC
NO,NC
Empty Tube, System Alarm
3.6,3.8,20.5,22
0: OFF, 1: ON
35