Motor will not run
16
trouble sHootInG
•
Check valve restricted
•
Motor overload protection
switch has tripped
•
Extension cord is wrong
length or gauge
•
Loose electrical connections
•
Possible defective motor or
starting capacitor
•
Paint spray on internal motor
parts.
•
Fuse blown, circuit breaker
tripped
•
Tank pressure exceeds pres-
sure switch cut-in pressure
•
Pressure release valve on
pressure switch has not un-
loaded head pressure
•
Remove, clean or replace
•
See Motor Overload under Features.
•
Check proper gauge wire and cord
length. See Extension Cords under pg.
•
Contact a Bosch factory service center
or a Bosch authorized service center.
•
Contact a Bosch factory service center
or a Bosch authorized service center.
•
Contact a Bosch factory service center
or a Bosch authorized service center.
Do not operate the compressor in the
paint spray area. See flammable vapor
warning.
1. Check fuse box for blown fuse and replace
as necessary. Reset circuit breaker. Do
not use a fuse or circuit breaker with higher
rating than that specified for your particular
branch circuit.
2. Check for proper fuse. Use only a time de-
lay fuse.
3. Check for low voltage conditions and/or
proper extension cord.
4. Disconnect the other electrical appliances
from circuit or operate the compressor on
its own branch circuit.
•
Motor will start automatically when tank
pressure drops below cut-in pressure of
pressure switch.
•
Set the On/Off switch to OFF. If the
valve does not open, replace switch.
Contact a Bosch factory service center
or a Bosch authorized service center.
9.