Esquema de conexiones
Con contador de horas de funcionamiento
E
L
220-240V~50Hz
220-240V~50Hz
Schuko Plug
Schuko Plug
Schukostecker
Schukostecker
N
18
Wiring diagram with tank present & full tank & condensates pump reseting the PCB
Hour counter just counting the compressor operation time
S1
0/1
Alarm
PCB
JP11
J9
(XGNF06)
J5
J7
F
C
NA
CC
NF
N
H
RC
M1
M1
L
N
Time Counter
(Standard)
- Earthing / Erdung
E
- Common Line / Gemeinsame
N
- Line / Außenleiter
L
S1
- On-Off Switch / Geräteschalter 0/1
S2
- Micro switch
/ Mikroschalter Wippe Vollstand
(Tank Presence)
S3
- Micro Switch
(Tank Full) / Mikroschalter Wippe Vo
S4
- Humidistat / Hygrostat
L
- Red lamp
/ Signalleuchte " rot "
(Tank full)
M1
- Compressor / Kompressor
M2
- Fan motor / Lüftermotor
Y
- Two Way Valve / Abtau-Magnetventil
RC
- Running Capacitor / Motorbetriebskondensator
/ Zeit Zähler
H
- Time Counter
(Standard)
P
- Water Pump Socket / Wasserpumpe Stockdose
E
L
M2
M2
S4
S3
2
4
NTC 10kÙ
1
< 2°C
NTC 10kÙ
3°C > < 32°C
1
4
2
S2
Y Y
(Tank Präsenz)
l
lstand (Behälter voll)
(Behälter voll)
(Standard)
deshumidificador TTK 125 S
Water Pump (Optional)
Black
Black
Brown
Blue
Green/Yellow
PLUG
4
3
2
1
P
Full
Empty
Bucket
Bucket
Bucket
NC contact
HIGH LEVEL
FLOAT SWITCH
Brown
PURGE
SWITCH
NO contact
LOW LEVEL
FLOAT SWITCH
Red
Black
Motor
ES