Check Operation - Whirlpool L0801665 Instrucciones De Instalación

Estufa autonoma a gas
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Complete
Connection
1. Locate gas pressure regulator in the broiler.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
2. Check that the gas pressure regulator shutoff valve is in the
"ON" position.
GasPressure Regulator
\
3,
Front View /
Front
Side View//
Shutoff valve
"ON" Position
Open the manual shutoff valve in the gas supply line. The
valve is "open" when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
4. Test all connections by brushing on an approved noncorrosive
leak-detection
solution. Bubbles will show a leak. Correct any
leak found.
5. Close the broiler door.
6. Place burners, burner caps and grates on the cooktop.
Electrical
Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
7. Plug into a grounded 3 prong outlet.
Electronic
ignition
System
Cooktop and oven burners use electronic igniters in place of
standing pilots. When a cooktop control knob is turned to the
"LITE" position, the system creates a spark to light the burner.
This sparking continues until the control knob is turned to the
desired setting.
When the oven control is turned to the desired setting, a hot
surface igniter heats to a bright orange and ignites the gas.
No sparking occurs. The glow bar remains on while the burner
operates.
Check
Operation
of Cooktop
Burners
1. If control panel and knobs were
eo
removed earlier, reinstall knobs,
co
2. Push in and turn each surface
unit control knob to "LITE"
position. The flame should light
LO
within 4 seconds.
3. Turn control knob to "HI"
position after burner lights.
4. Check each cooktop burner for
ME_
proper flame. The small inner
cone should have a very distinct blue
flame 1/4" (6.4 mm)to 1/2" (13 mm)
cone
long. The outer cone is not as distinct
as the inner cone.
inner
cone
5. Turn the control knob quickly to the "LO"
position after the burner lights. If the
flame goes out, turn the control knob to
the "OFF" position.
6. Check each cooktop burner for proper low flame. The low
flame should be a minimum, steady blue flame. The flame size
should be 1/4" to 3/8" (6.4 mm to 9.5 mm) high.
If the low flame needs adjusting:
1. Turn control knob to the "LO" setting and remove control
knob.
2. Insert a small flat-blade screwdriver into the valve stem. Turn
the valve adjusting screw to obtain the smallest flame that will
not go out when the control of a cold burner is quickly turned
from "HI" to "LO". Turn right to decrease flame height. Turn
left to increase flame height. Repeat for other cooktop burners
as needed.
A. Valvestem
3. Replace control knob.
10
Tabla de contenido
loading

Tabla de contenido