TiSUN SIMPLEX Guia Del Usuario página 12

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
Others:
Sensors error:
Collector sensor (T1):
Tank sensor (T2):
Extra sensor (T3):
Corresponding value for sensor PT1000:
(To be check with an Ohmmeter, only when the sensor is
disconnected)
-10°C / -14°F
0°C / 32°F
10°C / 50°F
20°C / 68°F
30°C / 86°F
40°C / 104°F
50°C / 122°F
60°C / 140°F
70°C / 158°F
80°C / 176°F
90°C / 194°F
100°C / 212°F
120°C / 248°F
140°C / 284°F
The pump P1 is stopped (Err 1 and
concerning LED blinks).
The pump P1 is stopped (Err 2 and
concerning LED blinks).
The additional heat is stopped. (Err 3)
960 ohms
1000 ohms
1039 ohms
1077 ohms
1116 ohms
1155 ohms
1194 ohms
1232 ohms
1271 ohms
1309 ohms
1347 ohms
1385 ohms
1461 ohms
1535 ohms