MADE IN FRANCE
MADE IN FRANCE
CONNECTION ON A GENERATOR
The machine can work with generators as long as the auxiliary power matches these requirements :
- The voltage must be AC, always set as specified, and the peak voltage below 400V,
- The frequency must be between 50 and 60 Hz.
It is imperative to check these requirements as several generators generate high voltage peaks that can damage these
machines.
USE WITH EXTENSION CABLES
All extension cables must have an adequate size and section, relative to the machine's voltage.
Use an extension that complies with national safety regulations.
TORCH SETUP
The torches are cooled with ambient air and do not require any special cooling.
1 - CONSUMABLES LIFE CYCLE
The replacement frequency of the Plasma's consumables depends on several factors:
• The metal thickness.
• The average cutting time
• The air quality (presence of oil, humidity or other contaminants).
• The metal piercing or the cut from the edge.
• The adequate distance between the torch and the part when cutting.
In normal conditions :
- During manual cutting, the electrode wears out first.
Torch consumables :
040229 (K35F)
040182 (K25)
Nozzle
2 - INSTALLATION OF THE TORCH CONSUMABLES :
Unplug the unit before changing consumables.
To use the torch, a complete set of consumables must be installed in the correct order: electrode, diffuser, tip and nozzle.
16
EASYCUT K25 / EASYCUT K35F
Voltage input
230 V
040212
040175
Tip
Di user
Nozzle
Tip
Section of extension cable (<45m)
6 mm²
040168
Electrode
Diffuser
Electrode
EN
4 m
Torch