The hour meter indicates that the lamp must be replaced as follows:
From hour meter reading672 the display flashes each second. The lamp should be replaced within
weeks.
From hour meter reading336 the display flashes each half second. The lamp should be replaced
within 2 weeks.
• From hour meter reading168 the display flashes each second. The lamp should be replaced within
week.
• When the hour meter reading reaches000, the numbers will flash quickly and the counter will no
longer count down. The lamp must be replaced.
DISASSEMBLY/MAINTENANCE
Always disconnect the power supply during maintenance/disassemblyf the device.
The device must be cleaned at least twice a year. When there is a significant amountf algal growth and/
or lime build-up in thenit the quartz sleeve (M) must be cleaned.
The special lamp must be replaced after the numberf hoursfperation has elapsed. The insidef the reactor
can be cleaned with a soft brush.
1. Let the water flowutf the device.
2. Unscrew the nut (N) and remove the lamp (K) from the fitting (L). Remove the lamp from the quartz
sleeve, and replace the special lamp (K) if necessary. Caution is advised as these are very delicate
parts.
3. Carefully remove the quartz sleeve (M) (see figure 3). Neverse force! CAUTION: Always wear
protective gloves and glasses.
4. Clean the quartz sleeve with an appropriate cleanser. Alwaysse a soft cloth to clean the sleeve and
avoid scratches.
5. Carefully place the lamp back in the quartz sleeve, fit the O-ring (T) backnto the quartz sleeve and
connect the lamp (K) to the fitting (L). Screw the nut (N) backnto the housing.
If the housingr the electrical section must be replaced, the earthing must first be disconnected from the
housing. Please read the Installation and Disassembly section before installing a new housingr electrical
section. Make sure you save the various separate parts for the earth connection. These are not supplied
with a new housingr electrical section. If in doubt about the connection, consult a qualified installer.
For the safety instructions and termsf guarantee we would like to
refer to the general UV-C manual from VGE International B.V.