tEcHnIcAL dAtA
metering chamber
moist part materials
inlet connection
Outlet connection
maximum working pressure
Burst pressure
Compatible fluids
flow range
Viscosity range
working temperature
Pressure loss at maximum flow
Precision
Pulse ratio
Power supply
solenoid valve compatibility
weight
This device complies with Part 15 of the fCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
That may cause undesired operation.
* Only applied to U meter+ model, which comprises a wireless kit.
DimensiOns
6
838 841 R. 12/18
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
Oval gear meter
Aluminium, Vectra, Stainless Steel, NBR
1/2"BSP and flange
1/2"BSP and flange with o-ring seating
100 bar (1450 psi)
150 bar (2175 psi)
Oil, glycol, coolant solutions
1-30 l/min, 0.25-8 gal/min (depending on fluid viscosity and temperature)
8 to 2000 cSt
-10 ºC to 60 ºC (14 to 140 ºF)
3 bar
±0.5% (after calibration)
328 ppl (1241,4 ppg)
24V AC/DC 50/60 Hz
24V DC (configuration needed) Maximum power 30W
500 g ( 1.1 lb)