Operating instructions and warnings
Instructions
The control board is ready to receive instructions
Scroll down the parameters until you visualize P007
Confirm! The control board awaits a further confirmation
Confirm by pressing on the OK button. The procedure starts
All parameters are now set at their original value
Scroll down the parameters until you visualise "----". The control board awaits
further instructions
8.6
Safety devices
DEA 202RR control board allows installers to set up installations that truly comply with European regu-
lations concerning automated garage doors and gates.
More specifically, this control board allows you to comply with the limits set by the same regulations as
to impact forces in case of collision with obstacles.
DEA 203RR control board is equipped with a built-in anti-crush safety device that allows you to comply
with the limits imposed by the above mentioned regulations in most installations. In particular, you can
adjust the anti-crush safety device sensitivity by properly setting the value assigned to the following para-
meters
(see also "8.4 Personalization of working parameters "):
• P014 motor 1 force in opening: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity)
• P015 motor 1 force in closing: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity)
• P016 motor 2 force in opening: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity)
• P017 motor 2 force in closing: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity)
In case of operators without encoder, the opening/closing differentiated sensitivity is not available, and
the parameters to set are the following:
• P014 motor force 1: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity)
• P016 motor force 2: from 30 (min. force, max sensitivity) to 100 (max force, neutralized sensitivity)
In case the gate structural features do not allow you to comply with the above force limits, it is possible
to use external safety devices inputs (terminal n° 24 and 25). "SIC1" and "SIC2" inputs can be configured
by setting properly parameter n° 18:
•P018 = 0 "safety rib" mode functioning: "SIC1" = safety rib operator 1 input, "SIC2" = safety rib ope-
rator 2 input. When 1 of the two inputs is activated, it stops the movement of both operators.
•P018 = 1 "photoelectric barriers" mode functioning: you can use either "SIC1" or "SIC2" or both of
them, but remember to short-circuit the unused input. When one of the two inputs is activated, the move-
ment of both motors is stopped.
If you power external safety devices through + 24VSIC output (terminal n°17), their proper working is
tested before each manoeuvre.
8.7
Messages shown on the display
202RR control board allows you to visualize on the display several messages concerning its working
status and any malfunction:
Message
Gate is closed
22
Gate is open
Opening under way
Closing under way
While in step-by-step mode, the control board awaits further instructions after a start command
Stop command received
Sic1 or sic2 activated while working in barrier mode
Function
Description
MESSAGES CONCERNING WORKING STATUS
Display