Pay careful attention when the pump is operated in manual mode.
The pump must be placed in a stable position inside a trap or in the lowest part of the place where it is
installed.
The float must be able to move freely while the pump is in operation, so the recommended dimensions for
the trap are 40x40 cm.
It is absolutely essential to prevent any risk of the pump freezing. In the event of freezing temperatures,
remove the pump from the liquid, empty it and keep it in a place where it cannot freeze.
Overload protection
The pump has a thermal overload safety device. In the event of any overheating of the motor, this device
automatically switches off the pump. The cooling time is roughly 15 to 20 minutes, then the pump automatically
comes on again. If the overload cutout is tripped, it is essential to identify and deal with the cause of the
overheating. See Troubleshooting.

5. TECHNICAL DATA

Voltage/frequency
Power
Max flow rate
Maximum head

6. TROUBLESHOOTING

Before taking any troubleshooting action, disconnect the pump from the power supply (i.e. remove the
plug from the socket).
If there is any damage to the power cord or pump, any necessary repairs or replacements must be handled
by the manufacturer or his authorized customer support service, or by an equally-qualified party, in order
to prevent all risks.
Fault
The motor does not start or
makes no noise.
The pump delivers no water.
The pump does not stop.
The flow rate is too low.
The pump stops after a brief
period of operation.
V 230-240/50 Hz
1000 W
3
19 m
/h
11 m
Possible causes
A. Make sure the motor is powered.
B. The pump is not enabled by the float.
A. The suction grid or piping are clogged.
B. The impeller is worn or stuck.
C. The required head is too high for the
characteristics of the pump.
A. The pump is not disabled by the float.
A. Make sure the suction grid is not partially
clogged.
B. Make sure the impeller or delivery pipe
are not partially clogged or fouled.
A. The thermal cutout stops the pump.
B. - Make sure the float can move
- Increase the depth of the trap.
A. Remove the obstruction.
B. Replace the impeller or remove the
obstruction.
A. Make sure the float can move freely.
A. Remove any obstructions.
B. Remove any obstructions.
A. - Make sure the fluid being pumped
- Make sure the temperature of the
- Make sure there is no solid body
4
Solutions
freely.
is not too dense, causing the
motor to overheat.
water is not too high.
obstructing the impeller.