en
the factory (see technical data). However, if desi-
red, you can adjust the setting as desired at the
pressure switch (10).
Checking the inlet pressure
1. Unplug the electric cable from the socket.
2. Open the pressure line and drain the water off
until the pump is completely empty.
3. Check the inlet pressure at the diaphragm (5).
TROUBLESHOOTING
CAUTION!
Before you attempt to remedy any malfunction of your domestic water system, pull the plug to
prevent injury or death due to electrocution!
Fault
Motor does not run.
System runs but does not pump
out liquid.
System is only pumping out li-
quid very slowly or weakly.
16
4. The pressure should be approx. 1.5 bar. Cor-
5. Put the domestic water system into operation
DISPOSAL
Cause
Thermal switch has switched
off.
No power.
Suction hose is not immersed in
the liquid to be pumped.
Suction hose is blocked.
Pressure line is blocked.
Suction height is too great.
Pump sucks air
Pump is dry.
Suction hose is blocked.
Suction height is too great.
Pressure hose diameter is too
small.
Pumping height is too great.
rect the pressure if needed.
as set out in the instructions.
Do not dispose of worn-out machines
or spent batteries (including recharge-
able batteries) in domestic waste!
The packaging, machine and accessories
are made from recyclable materials and
must be disposed of accordingly.
Solution
Wait until the thermal switch has
automatically switched the pump
on again. Check the tempera-
ture of the liquid. Have the pump
checked.
Have the power supply checked
by a qualified electrician.
Make sure that the suction hose
is at least 30 cm beneath the
surface.
DANGER! Risk of injury due to
hot water! Clear blockage in suc-
tion hose.
DANGER! Risk of injury due
to hot water! Clear blockage in
pressure line.
Lower suction height.
Check all connection hoses and
filter cover for tightness.
Fill the pump with water.
Clear the blockage.
Lower suction height.
Attach a pressure hose with a
larger diameter.
Lower pumping height.