the tank runs out of water or if the unit runs in dry operation.
- To restart the humidifier, disconnect the plug and wait 5 minutes for it to
cool down. Top up with water and restart from (point 4).
MAINTENANCE AND CLEANING
Always disconnect the power cable (2.1) and wait 30 minutes for the device to cool
down, before cleaning. For ex-tended periods of non-use, store the device, only
when it is clean and dry, inside its box.
ATTENTION: Presence of excessive scale may be found on the resistance due
to lack of or poor maintenance and cleaning operations. This may be the cause
of malfunctions on the ON/OFF night light (2.7) even when the tank is full.
Daily cleaning/maintenance:
1- Remove the heating unit (2) by rotating it and pulling it upwards (Fig. B).
2- Fully drain the tank. Ensure that water drains from the hole (1.3) (Fig. G).
3- Before refilling the tank, clean and rinse a couple of times with abundant water. If
you do not use it immediately, drain and dry with a cloth.
Warning: DO NOT use abrasive detergents or brushes. DO NOT leave water in the
water tank when the device is not running. This prevents bacteria from forming in
the tank.
Weekly cleaning/ maintenance:
1- On a weekly basis, clean the humidifier as described in "Daily cleaning".
2- Clean the heating unit. Immerse the heating unit into 10 cm of solution containing
50% water and 50% white vinegar for 10 minutes. Lastly, rinse abundantly with
hot water (approximately 40 °C) see (Fig. H).
End of season cleaning/maintenance:
1- Clean the humidifier as described in "Weekly cleaning".
2- Descale the resistance (2.6), by removing the cap of the heating unit (2.5) rotating
it anti-clockwise (fig. I). Use a regular sponge to remove the scale (fig. L).
12