Remedy of faults

Malfunction
The unit does not start up
Insufficient fountain height

Maintenance and cleaning

WARNING
Possible death or severe injury from hazardous electrical voltage!
 Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
 Isolate the device (disconnect from the power supply) before carrying out any work on it.
If necessary, clean the unit with clear water using a soft brush.
 Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function
of the unit.
 Recommended cleaning agent for removing stubborn limescale deposits:
– Vinegar- and chlorine-free household cleaning agent.
 After cleaning, thoroughly rinse all parts in clean water.
Replacing the impeller unit
How to proceed:
 D
1. Pull off the pump casing.
2. Pull the impeller unit out of the motor housing.
3. Assemble the pump in the reverse order.
Storage
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit:
 Thoroughly clean the unit, check it for damage and replace any damaged parts.
 Store the pump submerged and in a frost-free environment.
 Protect open plug connections from moisture and dirt.
Wear parts
 Impeller unit
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided. Render
the unit unusable beforehand by cutting the cables.
12
Cause
No mains voltage
Impeller unit blocked
Regulator closed too far
Pump casing or impeller unit soiled, hose
blocked
Hose defective
Hose kinked
Impeller unit worn
Remedy
Check the mains voltage
Clean
Adjust regulator
Clean
Replace
Route hose in a straight line
Replace impeller unit