Fiap Air Active Solar SET 150 Guia De Inicio Rapido página 3

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
FIAP Air Active Solar SET
GB
Information about this operating manual
Please read the operating instructions and familiarise yourself with the unit prior to using it for the first
time. Adhere to the safety information for the correct and safe use of the unit. Please keep these
operating instructions in a safe place! Also hand over the operating instructions when passing the
unit on to a new owner. Ensure that all work with this unit is only carried out in accordance with these
instructions.
Intended use
The series FIAP Air Active Solar SET, termed unit is a solar-powered ventilation pump. The device
may only be operated in normal pond water with a water temperature of +4 ° C to +35 ° C.
The device is suitable for use in ponds, swimming ponds in accordance with national regulations and
installer of water containers on patios.
Use other than that intended
Danger to persons can emanate from this unit if it is not used in accordance with the intended use and
in the case of misuse. If used for purposes other than that intended, our warranty and operating permit
will become null and void.
CE Manufacturer's Declaration
We declare conformity in the sense of the EC directive, EMC directive (2004/108/EC) as well as the
low voltage directive (2006/95/EC). The following harmonised standards apply:
EN 55014-1, EN 55014-2, EN 60335-1, EN 60335-2-41, EN 60598-1, EN 60598-2-18, EN 61000-3-2,
EN 61000-3-3, EN 61558-2-6
Safety information
The company FIAP has built this unit according to the state of the art and the valid safety regulations.
Despite the above, hazards for persons and assets can emanate from this unit if it is used in an
improper manner or not in accordance with its intended use, or if the safety instructions are ignored.
For safety reasons, children and young persons under 16 years of age as well as persons who
cannot recognise possible danger or who are not familiar with these operating instructions, are
not permitted to use the unit. Hazards encountered by the combination of water and electricity.
The combination of water and electricity can lead to death or severe injury from electrocution, if the unit
is incorrectly connected or misused. Prior to reaching into the water, always disconnect the power
supply to all units used in the water.
Correct electrical installation
Electrical installations at garden ponds must meet the international and national regulations valid for
installers. Especially adhere to DIN VDE 0100 and DIN VDE 0702. Only use cabes admitted for
external use and meeting DIN VDE 0620. Ensure that the transformer is protected by a rated fault
current of max. 30 mA via a fault current protection device. Only connect the transformer when the
electrical data of the power supply is identical to that on the type plate. Only operate the transformer
when plugged into a correctly fitted socket. For your own safety, consult a qualified electrician when
you have questions or encounter problems.
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
5
www.fiap.com
FIAP Air Active Solar SET
Safe operation of the unit
Keep socket and power plug dry. Route the power cables so that damage is excluded. Do not carry or
pull the units by the connection cables. The power connection cables cannot be replaced. If the cable
is damaged, the entire unit has to be disposed of. Never run the pump without water! Otherwise the
pump will be destroyed. Never use the pump for fluids other than water. Other fluids could destroy the
unit. Never open the unit or its attendant components, unless this is explicitly mentioned in the
operating instructions. Never carry out technical modifications to the unit. Only use original spare parts
and original accessories for the unit. Only have repairs carried out by authorised customer service
points. Never look directly into the light source of the unit. The light beam's intensity could irreversibly
damage the retina.
Commissioning
Unroll the cable and the supplied air hose completely. Connect one end of the air hose to the air outlet
connection of the solar pump. The other end of the air hose to connect the air stone. The check valve
can be installed between the solar-powered air pump and air stone.
Adjust the air pump at the pond edge on. The pump should always be placed above the water table.
Mount the spike at the solar module and connect the plug of the air pump to the socket of the solar
module. Place the solar panel on a sunny, shadow-free place.
Note:
The pump is not waterproof, you never ask this in the water.
The pump sucks the air required at the bottom. The two slots must always be free, and it must not
enter the water.
Cleaning and maintenance
It must be cleaned regularly, the solar module with a damp cloth. If the air stone may be clogged,
replace it immediately.
Storage / wintering
Frost must be uninstalled when the unit. Perform a thorough cleaning, check the unit for damage.
Disposal
The device should be disposed of in accordance with national law.
Check with your dealer.
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
6
www.fiap.com
loading

Este manual también es adecuado para:

2947