6.16 Capacity limitation
This function offers the possibility of reducing the
maximum pump capacity (MAX. CAP.). It influences
the functions in which the pump is normally operating
at maximum capacity.
Under normal operating conditions, the pump cannot
operate at a capacity which is higher than the one
stated in the display. This does not apply to the
maximum capacity button
6.3 Priming/venting of
pump.
Set maximum capacity
Operating display
Fig. 17
6.17 Counters
The pump can display "non-resettable" counters for:
•
"QUANTITY"
Accumulated value of dosed quantity in liters or
US gallons.
•
"STROKES"
Accumulated number of dosing strokes.
•
"HOURS"
Accumulated number of operating hours.
•
"POWER ON"
Accumulated number of times the electricity
supply has been switched on.
, see section
100%
Total dosed
quantity
Total number
of strokes
Total number of
operating hours
Total number
of starts
Operating display
Fig. 18
23