CONNECTION-WIRE DIAGRAM (See the right figure)
SENSOR INFORMATION:
Height of installation:2-2.2m
TEST:
- Turn the TIME knob anti-clockwise on the minimum (10s).Turn the
LUX knob clockwise on the maximum (sun).
- Switch on the power; the sensor and its connected lamp will have
no signal at the beginning. After Warm-up 30sec, the sensor can start
work .If the sensor receives the induction signal, the lamp will turn on.
While there is no another induction signal any more, the load should
stop working within 10sec±3sec and the lamp would turn off.
- Turn LUX knob anti-clockwise on the minimum (3). If the ambient
light is more than 3LUX, the sensor would not work and the lamp stop
working too. If the ambient light is less than 3LUX (darkness), the
sensor would work. Under no induction signal condition, the sensor
should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to
not work! If the lamp is more than 60W, the distance between lamp and sensor should be 60cm at least.
SOME PROBLEM AND SOLVED WAY:
- The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
- The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to receive the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required in the instruction.
e. Please check if the moving orientation is correct.
- The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is set to the maximum position.
c. Please check if the power corresponds to the instruction.
The wires come in
and out from the bottom
The wires come in
and out from the side
Detection Distance: Max.6m
(SUN) position, otherwise the sensor lamp could
loading