Translation of the original instructions
PROCEDURE TO CHANGE THE PIECE OF FABRIC OVER THE BOLT INDUCTOR
1. Delicately cut the Silicone which maintains the
fabric in position. Use a wedge or a spatula.
2. Completely remove the protection and ensure that
the remaining glue is removed.
PROCEDURE TO CHANGE THE PIECE OF FABRIC OVER THE GLASS INDUCTOR
1. Remove the damaged fabric by using a wedge or a
spatula
2. Clean the surface
4
INDUCTORS PROTECTION
3. Apply a dose of Silicone. Monitor the quantity
applied as it might overflow
Spreading is recommended
4. Place the protection and mark the angle with a
spatula or a wedge.
Wait 24 hours before use.
3. Apply a dose of Silicone
4. Place the protection
Press it with a wedge or a spatula to ensure it is even.
Wait 24H, the time for it to stick.
EN