4. SAFETY PRECAUTIONS

4.1. Before connecting the showcase to the circuit of ~220 V, install before the
receptacle an automatic circuit breaker for 6.3 A.
4.2. The showcase shall be connected to the grid with a grounding conductor.
Grounding shall be checked from time to time pursuant to Operational regulations for
customers' electrical equipment.
4.3. Upon commissioning the Product and later, at least once a year, make routine
inspection including the following actions:
-
inspection of all protective devices and automatic nodes;
-
qualification inspection of all electric wirings and feeder cable;
-
qualification inspection of the connection of grounding conductors to the Product;
-
meggering of the feeder cable;
-
inspection of resistance between the casing of the product and nearby grounded
equipment;
-
Inspection data shall be put into the preventative maintenance file (Annex 3).
4.4. THE FOLLOWING SHALL NEVER BE DONE:
-
Product operation in case of damaged wire insulation and failure of the ground
wire
-
Product operation without grounding
-
Long-term operation of the product in extreme conditions at the temperature of
above 25°С or below 12°С
-
Application of sharp objects to eliminate snow cover from the refrigerant
evaporator box
-
Operation of the product whose glass screens are damaged and have sharp edges;
-
Operation of the product with the supply grid with the voltage other than 220 V
(+10-15)%
-
Release of fluorocarbon refrigerant from the Product to the atmosphere.
4.5. Maintenance, adjustment, troubleshooting, and sanitary treatment of the product
shall be done with the latter disconnected from the mains.
4.6. If any showings of abnormal operation of the Product occur, if fluorocarbon
refrigerant leakage is detected, switch the showcase off the power supply and call for a
technician.