ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
WHIRLPOOL PLUS AIR BATH COMBINATIONS
The whirlpool pump should be installed on a 120 vac, 15 amp dedicated circuit. The blower/lights should be installed
on a separate 120 vac, 15 amp dedicated circuit.. The circuit should be hard-wired from the electrical power supply
panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third
wire, earth ground, are essential. A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT IS REQUIRED IF THE
OPTIONAL HEATER IS INSTALLED (SEE INSTALLATION INSTRUCTIONS
NUMBER – 494-1000). NOTE: DO NOT USE A WALL MOUNTED TIMER TO CONTROL THE HEATER.
ON/OFF PUMP
OPTIONAL
HEATER
PUMP INSTRUCTIONS
1. ON/OFF PUMP:
1st Press — The blower starts. 2nd Press — The blower stops.
2. PUMP SPEED VARIATION:
1st Press — Press & hold to increase the pump speed,
release pressure at the desired speed.
2nd Press — Press & hold to decrease the pump speed,
release pressure at the desired speed.
3. PUMP CYCLES:
1st Press — Wave Cycle - Speed goes gradually from maximum to minimum.
2nd Press — Pulse Cycle - Speed goes rapidly from maximum to minimum.
3rd Press — Return to medium speed.
BLOWER INSTRUCTIONS
1. ON/OFF BLOWER:
1st Press — The blower starts. 2nd Press — The blower stops.
2. SPEED VARIATION:
1st Press — Press & hold to increase the blower speed,
release pressure at the desired speed.
2nd Press — Press & hold to decrease the blower speed,
release pressure at the desired speed.
3. BLOWER CYCLES:
1st Press — Wave Cycle - Speed goes gradually from maximum to minimum.
2nd Press — Pulse Cycle - Speed goes from minimum the straight
back to maximum.
ADVANCE PROGRAMMING
INTEGRATED 20 MINUTE AUTOMATIC TIMER:
Integrated 20 minute automatic timer on each system.
DRYING CYCLE:
A 1 minute automatic drying cycle will start 20 minutes after the blower is turned off.
TOTAL MASSAGE CIRCUIT WITH OPTIONAL HEATER
BACK OF 6 BTN
CONTROL
TMS-P / TIMER
CONTROL
120V / 15 AMP
MALE PLUG
120V / 60 Hz
15 AMP GFCI
BLOWER
ELECTRICAL
FEED
120V / 60 Hz
15 AMP GFCI
GFCI
GFCI
GFCI
CHROMATHERAPY INSTRUCTIONS
1. ON/OFF CHROMATHERAPY:
1st Press — Starts the chromatherapy in white.
White is only available when system starts.
2nd Press — Chromatherapy stops.
2. PREVIOUS COLOR / SPEED INCREASE:
Press — Press return to to the previous color.
On Rainbow cycle: increase the speed.
Hold to quickly change between colors.
Release at the desired color.
3. NEXT COLOR / SPEED DECREASE:
Press — Press return to to the next color.
On Rainbow cycle: decrease the speed.
Hold to quickly change between colors.
Release at the desired color.
4. CHROMATHERAPY CYCLE:
1st Press — Rainbow cycle starts.
2nd Press — Stops on current color.
3rd Press — Turquoise.
4th Press — Back to rainbow mode.
11
SUPPLIED WITH THE HEATER MODEL
LIGHT KEY PAD
TMS-VARIABLE
CONTROL
UP/HAUT
OUTPUTINPUT
W/D KEYPAD AUX
CONTROL BOX
120V / 60 Hz
15 AMP GFCI
754764-100 Rev 8 5/21
LIGHT