It is important to clean the water tank, the vaporization area, and the air inlet grids located under
the appliance regularly.
Never use detergents or scouring products to clean your appliance.
Never immerse the appliance, the plug, or the power cord in water or any other liquid.
We recommend to use cold boiled water or distilled water.
• Cleaning the tank:
1- Clean the tank using soapy water and dry it with a soft dry rag.
2- Make sure to pull out the water from the appliance, and dry it before you store it for a long
periode of time.
IMPORTANT: Empty the water inside the product by following the indications on the appliance (empty
it on the right side). Never put water in the piezo tank. Don't put water in the air oultet of the piezo.
• Cleaning the vaporization compartment (arround the piezo disc 13), the heating element and
the piezo disc.
Rinse regularly (every 3 days) the water base with fresh water and dry it with soft dry rag.
IMPORTANT : make sure that no water gets into the fan air outlet (16).
Regular cleaning of the piezo disc and heating element will avoid scaling. Do not use hard or
abrasive utensils, only use soft materials with the device.
In case of scaling appearance, please refer to the paragraph "SCALE CLEANING AND ANTISCALE
CARTRIDGE".
WARNING : we recommend to give the heating element and the piezo disc a complete clean as
soon as scaling sediment appeared on them to preserve same level of performances.
To avoid any damage to your product, please properly follow the cleaning instructions,
especially not letting water into the fan air outlet (4).
IMPORTANT: Never use abrasive cleaners as these are likely to spoil the appearance of your
appliance. Instead, clean your appliance with a slightly moist rag.
If you have any questions, please see the ROWENTA international guarantee card enclosed with
this product, where you will find the Consumer Service contact details.
SCALE CLEANING AND ANTISCALE CARTRIDGE
INSTRUCTIONS FOR USE:
1- Turn off the unit and remove the lid.
(IMPORTANT, make sure that no water gets into the fan air outlet).
2- Fill the water tank with 1 centimeter of vineger in the water tank and around the piezo area and
wait for 1 hour to take effect.
3- Empty and remove the scale using a slightly moist rag.
4- Rinse out the water tank and the piezo area with fresh tap water.
(IMPORTANT, make sure that no water gets into the fan air outlet).
5- Your appliance is now ready to be used again.
WARNING: Make sure to properly rinse the tank and the piezo area before using the product.
If you want to prevent the scaling of your water tank, use the ANTISCALE CARTRIDGE.
The Aqua Boost models provided with an anti-scale cartridge are the following:
• HD4040
• HD4045
The anti-scale cartridge is also sold as an accessory (XD6400F0), and is compatible with all
HU40XX and HD40XX models.

INSTRUCTIONS OF USE:

Cartridge
Cartridge in
Cartridge out
22
22
As soon as unpleasant odours or white dust are noticeable, change the anti-scale cartridge. For
any questions, please refer to the international warranty card included with this product where
you will find the Customer Service contact details.
Your replacement cartridge is available in the ANTISCALE CARTRIDGE, sold as an accessory under
the following code : XD6400F0
STORAGE
When the appliance is not in use, it should be stored in a dry place.
Make sure to empty the tank, clean and dry the appliance before storing it.

IN THE EVENT OF A PROBLEM

Never dismantle your appliance yourself. An incorrectly repaired appliance can be a danger to the user.
Before contacting an approved Service Centre from our network, make sure that the appliance is
in the normal operating position and the air intake and outlet grills are totally unobstructed.
P roblem
Possible Cause
The target humidity is reached.
The water level indicator is
blinking.
The lid isn't well positionned.
The appliance does
not work when swit-
The appliance isn't on a flat
ched on
surface.
The water level required has
not yet reached the vaporization
compartment.
The RH% of the room is over 90%.
There is natural or artificial air
replacement in the room which
interfere the increase of HR%.
The air inlet grids and nozzle
could be blocked.
The humidification
capacity is too low
There is too much scale in the
water basin or on the piezo part.
The Humidity selected rate is
too low.
The appliance is working in
CONTINUOUS MODE.
The ambient humidity
is too high
The humidity target is too high. Select a lower RH% target.
There is condensation
The room temperature is too
in the room
low.
The appliance is unstable.
The appliance is too
There may be resonance in
noisy
water tank due to low water
level.
What to do
Increase the target humidity in MANUAL
MODE or select CONTINUOUS MODE.
Refill the water tank.
Check the positionning of the lid.
Check the positioning of the appliance
(tilt).
Wait arround 2-3 minutes after filling the
product.
Wait till the RH% of the room gets below 80%.
Check if doors and windows are closed.
Check if there is no air conditioning
working in the room.
Remove any blocking items from the
grids and the nozzle.
Clean the water base according to Main-
tenance Instructions.
Increase Vaporization volume level in
MANUAL MODE.
Increase Humidity setting in MANUAL
MODE.
Change the mode.
Heat up the room or turn down the hu-
midity target.
Place the appliance on a flat and stable
surface.
Refill the water tank.