Indicator Lights - Telstar TDH030110MD Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

• Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop function.
• When LED display window displays the code of P2, the Auto Start/Stop function will also be cancelled.
Down/Up buttons
• Humidity Set Control Buttons
The humidity level can be set within a range of 35%RH(Relative Humidity) to 85%RH
(Relative Humidity) in 5% increments.For drier air, press the
value(%).
For damper air, press the
Timer Set Control Buttons
Press to initiate the Auto start and Auto stop feature, in conjuction with the

Indicator lights

On
Timer on light
Full
Bucket full light
Timer off light
Auto defrost
Auto defrost light
Power button
Press to turn the dehumidifier on and off.
LED display
Shows the set % humidity level from 35% to 85% or auto start/stop time (0~24) while setting, then shows the
actual (±5% accuracy) room % humidity level in a range of 30% RH(Relative Humidity) to 90%RH(Relative
Humidity).
Error Codes:
AS- Humidity sensor error;
ES- Temperature sensor error;
E3- Unit malfunction;
Eb- Bucket is removed or not in right position--
Replace the bucket in the right position. (only available for the unit with pump feature).
button and set a higher percent value(%).
22
DEHUMIDIFIER
TDH030110MD
button and set to a lower percent
and
buttons.