DIMENSION REQUIREMENTS
Ceiling
Opening (L)
Opening (W)
7-1/2 in.
WIRING DIAGRAM
NEW CONSTRUCTION INSTALLATION INSTRUCTIONS
Review all safety precautions. Make sure electricity
at the breaker box is turned off before beginning
installation.
1.
Cut an opening that measures 7.5 in. x 7.25 in.
2.
Attach the duct connetor to the fan housing.
Ceiling
Ceiling
Opening (H)
7-1/4 in.
5-3/4 in.
QUICK CONNECTOR INSTRUCTIONS
To be sold only with installation instructions.
WARNING:
Wiring must comply with all appliable electrical
codes. Turn OFF power before removing or installing connectors.
WARNING:
COPPER TO COPPER ONLY. Do not use aluminum wire.
CAUTION:
Accessory part (quick connector) should meet
installation instructions below.
NOTE:
The connector is reusable on solid wires of the same wire gage
or smaller. Do not reuse the connector on stranded wires.
• Strip wires 3/8 in. - 1/2 in.
• Grip the wire firmly and push the
stripped end of the wire into the
open port of the connector.
Use only one connector
per port.
• Verify the stripped end of the
wires is fully inserted to the
back of the connector.
NOTE:
Important wire information. Maximum temperature rating 221˚F
(105˚C). 600 volts maximum for building wire and 1,000 volts maximum for
building wire and 1,000 volts maximum in signs and lighting fixtures.
The acceptable wire range includes: Solid: 12-18 AWG.
1
2
5
Quick
connect
House
wires
Product
wires