DESCRIPTION
Congratulations with your purchase of this product.
MINIDIM RGB 2 is a constant voltage driver for RGB LED devices control. It can operate on several modes: Through DMX signal (3 channels), Manual (with intensity
adjustment by dip assignation) or Program (5 built-in programs with intensity and speed control). It allows to connect up to 6 A load on its output.
MINIDIM RGB 2 can be used in a standard DIN rail using the separate accesories for its fixation.
BOX CONTENTS
You should be in possession of the following items:
1
MINIDIM RGB 2
1 Manual
Check for transport damage.
If you discover transport damage after unpacking the equipment, inform the hauler immediately. Never connect a damaged device. You
Power Requirement
12~24VDC,6.5AMax.
Output
OPERATION GUIDE
1. DMX Control Mode (DMX addressing)
In this mode, the dip-switches 10 & 11 are flipped to OFF and 12 to ON. The unit needs 3 DMX channel for controlling: Red color is controlled by Channel 1.
Green color is controlled by Channel 2 and Blue color is controlled by Channel 3.
DMX is an universal binary language used as a form of communication between intelligent fixtures. Each Dip Switch represents a binary value.
Dip Switch 1 address equals 1
Dip Switch 2 address equals 2
Dip Switch 3 address equals 4
Dip Switch 4 address equals 8
Dip Switch 5 address equals 16
Dip Switch 6 address equals 32
Dip Switch 7 address equals 64
Dip Switch 8 address equals 128
Dip Switch 9 address equals 256
2.Manual Control Mode
In this mode, the dip-switches 10,12 are flipped to the OFF and 11 to ON. Flip the dip-switch 1~3 to set the intensity of Red LEDs, dip-switch
Green LEDs and dip-switch 7~9 to set the intensity of Blue LEDs. Please refer to the following table for further information.
3.Program Mode
In this mode, dip switches 11 & 12 are flipped to OFF and dip 10 to ON. With the dips number 1, 2 & 3, we can select one of five built-in programs. With dips 4, 5 & 6
it is possible to control the general dim level, and using dips 7, 8 & 9, it is possible to control the speed of these programs. See closed tables:
Program
Num. 1
1 0
0
1 2 3
1 2
Num. 2
0 1
0
1=
ON
Num. 3
1 1
0
Num. 4
0 0
1
Num. 5
1 0
1
0= OFF
Program 1: 7 colors changing without fade: Red, Red/Green, Green, Green/Blue, Blue, Blue/Red, White.
Program 2: 6 colors changing with fade: Red, Yellow, Green, Cyan, Blue, Purple.
Program 3: Cyan range. From Blue to Green with tone change.
Program 4: Yellow range: From Red to Green with tone change.
Program 5: Purple range: From Red to Blue with tone change.
CONNECTION DIAGRAM (EXAMPLE)
DMX control installation. Two different lines using one MINIDIM RGB 2 in DMX mode for each one. Dips 10, 11 & 12 setup on DMX mode and each MINIDIM RGB 2 with
different DMX starting address in order to make a more individual control.
PSU
24 VDC
6 A max.
PSU
24 VDC
6 A max.
MINIDIM RGB 2
User Manual
Oper. temperature
6A,Max.
Connection
Use the dip switches to set the DMX starting address
For example: Setting DMX address for 21.
Flip switches1,3,&5 to the
"ON"position
1=1
3=4
Dipswitches#
5=16
Intensity
Red
Green
(SW1~3)
(SW4~6)
0
000
000
14%
100
100
28%
010
010
43%
110
110
Intensity
Intensity
57%
0 0
1
0
0 0
0
71%
1 0
1
14%
1 0
0
28%
0 1
0
86%
0 1
1
43%
1 1
0
100%
1 1
1
o
o
-10 C to +50 C
Dimensions
Terminal Blocks
Weight
1 2 3 4 5 6 7 8 9 10
START
SWITCHES ON
CH#
1
1
2
2
3
1,2
3
4
5
1,3
2,3
6
7
1,2,3
8
4
9
1,4
Value
10
2,4
=21
Blue
Intensity
Red
(SW7~9)
(SW1~3)
000
57%
001
100
71%
101
010
86%
011
110
100%
111
Speed
Speed
4
5 6
57%
0
0 0
0
1=
ON
71%
14%
1 0
0
28%
0 1
0
86%
43%
1 1
0
0= OFF
100%
Up to 6 A load max. (100 x LED LINE 10 max.)
Up to 6 A load max. (100 x LED LINE 10 max.)
NOTE: For a better
understanding. the
square in white color
is considered the switch
in all pictures of this
user manual
may also contact your supplier.
50(L)x84(W)x28(H)mm
230g
1=
ON
11 12
0=
OFF
START
SWITCHES ON
CH#
DMX starting address
11
1,2,4
3,4
12
13
1,3,4
2,3,4
14
15
1,2,3,4
1 2 3 4 5 6 7 8 9 10
1,2,3,4,5,6,7,8,9
Green
Blue
(SW4~6)
(SW7~9)
001
001
1 2
1 2
3 4 5 6 7 8 9 10
101
101
011
011
Red
Green
111
111
7
8 9
0 0
1
1 0
1
1=
ON
1 2 3 4 5 6 7 8 9 10
0 1
1
1 1
1
0= OFF
EN
ON
1=
12
0=OFF
1=
ON
11 12
0=OFF
4~6 to set the intensity of
1=
ON
11 12
0=OFF
Blue
1=
ON
11 12
0=OFF
Rev. 14.10.01
loading

Resumen de contenidos para Work Pro W MINIDIM RGB 2

  • Página 1 CONNECTION DIAGRAM (EXAMPLE) DMX control installation. Two different lines using one MINIDIM RGB 2 in DMX mode for each one. Dips 10, 11 & 12 setup on DMX mode and each MINIDIM RGB 2 with different DMX starting address in order to make a more individual control.
  • Página 2 DIAGRAMA DE CONEXIONADO (EJEMPLO) Instalación con control DMX. Dos diferentes líneas usando un MINIDIM RGB 2 en modo DMX en cada una de ellas. Los Dips 10, 11 y 12 configurados en modo DMX y cada MINIDIM RGB 2 con una dirección de inicio DMX diferente.