PROBLEM
Seal leaks
The pump stops during
work

Parts List

Part
1
2
3
4
5
6
7
8
9
10
11

Assembly Diagram

For Professional Technical Support call 1-844-242-2475
POSSIBLE CAUSE
1. Worn seal.
2. Pump head is loose on motor.
1. Insufficient water source leads to
no-load protection
2. The impeller is locked by garbage
Description
Priming Plug
O-ring
Pump Gasket
Motor
Spring Washer
Screw
Water Retaining Washer
Mechanical Seal
Impeller
Pump Facing
Rubber Foot
CORRECTIVE ACTION
1. Replace seal.
2. Ensure proper assembly and check
for obstructions. Tighten bolts.
1. Check the water source and restart
the pump according to the operation
steps
2. Remove the pump body and clean up
the garbage