Preparations For Installation; Standard Fittings; Installation Position Selection - Gree GMV-ND28ZD/A-T Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Multi Variable Air Conditioners Floor and Ceiling Type Indoor Unit

3 Preparations for Installation

Note: Product graphics are only for reference. Please refer to actual products. Unspecified
measure unit is mm.

3.1 Standard Fittings

Use the following provided accessories according to the requirement.
No.
Name
1
Remote controller
2
Special nut
3
Special nut
4
M10X8 nut with washer
5
Insulation
6
Insulation
7
Installation Paperboard
8
Fastener

3.2 Installation Position Selection

(1) The location should be able to withstand the weight of unit.
(2) The water can be drained conveniently from drainage pipe.
(3) There should be no obstruction near air inlet and air outlet.
◆ Floor type
>600
◆ Ceiling type
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
Appearance
4-φ12
>600
>300
5
Q'ty
Usage
1+2
To control the indoor unit
1
To connect gas pipe
1
To connect liquid pipe
To be used together with the suspension
8
bolt for installing the unit.
1
To insulate the gas pipe
1
To insulate the liquid pipe
Locate the drill hole on ceiling
1
Or Wall
4
To fasten the sponge
>1000
Unit: mm

Capítulos

Tabla de contenido
loading

Tabla de contenido