Cleaning The Vacuum Cleaner - Rowenta CITY SPACE CYCLONIC RO252201 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
4. CLEANING THE HEPA FILTER (14B)
The air we breathe contains particles that can be allergenic: larva and dust mite faeces, mould, pollen,
smoke, and animal waste (hair, skin, saliva, urine). The finest of these particles penetrate deeply into the
respiratory system, where they can cause inflammation and alter the respiratory function as a whole.
(H)EPA ([High] Efficiency Air Particle Filter) filters retain even the smallest particles. Thanks to the (H)EPA
filter, the air that is expelled back into the room is cleaner than the air vacuumed.
Important!
Remember to clean the HEPA filter case (14) [black foam filter (14a) and HEPA filter (14b)] every month.
• Pull simultaneously on the opening clips (13d) of the HEPA filter case - Fig.19.
• Separate the black foam filter (14a) from the HEPA filter (14b) - Fig. 20.
• Turn the HEPA filter (14b) over and tap the dust into a dustbin - fig. 37.
• Then scrape the HEPA filter under warm water using the accessory (18b), then leave the HEPA filter to dry
for 24h - Fig. 38.
• Once the foam is completely dry, assemble the HEPA filter case (14): black foam filter (14a) and HEPA fil-
ter (14b) under the dust tray (13) – Fig. 22, then replace the dust tray inside its compartment (7) – Fig. 18.
• Ensure that the HEPA filter (14b) is completely dry before you put it back in the appliance.
Warning! Make sure that the whole filter system is well placed before starting your appliance again.
5. REPLACE THE FILTERING SYSTEM
5.1. HEPA FILTER CASE (14) - Ref. ZR0056 01
Important: Change the HEPA filter case (14) every 6 months.
The HEPA filter case (ref. ZR0056 01 is available at your local retail store or at one of our Authorized Service
Centres.
• Pull simultaneously on the opening clips (13d) of the HEPA filter case - Fig.19.
• Separate the black foam filter (14a) from the HEPA filter (14b) - Fig. 20.
• If the HEPA filter case (14) (black foam filter (14a) and HEPA filter (14b)) is damaged, throw it in the bin –
Fig. 39 - and replace it with a new HEPA filter case (ref. ZR0056 01).
• Assemble the HEPA filter case (14): black foam filter (14a) and HEPA filter (14b) under the dust tray (13) –
Fig. 22, then replace the dust tray inside its compartment (7) – Fig. 18.
5.2. MICROFILTER (8A) – Ref. ZR0056 01
Important: Change the microfilter* every 6 months.
The microfilter ref. ZR0056 01 is available at your local retail store or at one of our Authorized Service
Centres.
• Remove the motor protection grill (8b) - Fig. 40.
• Remove the microfilter (8a) – Fig. 41 – and keep the motor protection grill (8b).
• Throw the microfilter (8a) in the bin – Fig. 42.
• Place a new microfilter (8a) on the motor protection grill (8b) - Fig. 43.
• Slide the ledges into the slots - fig. 44.
• Screw on the motor protection grill (8b) - Fig. 45.
• Before placing back the dust tray, make sure that the motor protection grill is placed properly.

CLEANING THE VACUUM CLEANER

• Wipe the body of the vacuum cleaner and accessories with a soft damp cloth, then dry.
• Wipe the lid with a dry cloth - fig. 46.
• Do not use any detergents, or corrosive or abrasive products.
* According to model : this piece or accessory is specific to
certain models or can be bought separately.
12